A series of collaborations between various pharmaceutical companies and regulatory authorities concerning the analysis of biomolecules using capillary electrophoresis

被引:38
作者
Nunnally, B.
Park, S. S.
Patel, K.
Hong, M.
Zhang, X.
Wang, S. -X.
Rener, B.
Reed-Bogan, A.
Salas-Solano, O.
Lau, W.
Girard, M.
Carnegie, H.
Garcia-Canas, V.
Cheng, K. C.
Zeng, M.
Ruesch, M.
Frazier, R.
Jochheim, C.
Natarajan, K.
Jessop, K.
Saeed, M.
Moffatt, F.
Madren, S.
Thiam, S.
Altria, K.
机构
[1] Wyeth Res, Vaccine Analyt Dev, Sanford, NC 27330 USA
[2] Amgen Inc, Dept Pharmaceut, Thousand Oaks, CA 91320 USA
[3] Centacor Res & Dev Inc, Pharmaceut Dev, Radnor, PA 19087 USA
[4] Chiron Corp, Analyt Dev, Emeryville, CA 94608 USA
[5] Eli Lilly & Co, Lilly Corp Ctr, Lilly Res Labs, Bioprod Pharmaceut Res & Dev, Indianapolis, IN 46285 USA
[6] Genentech Inc, Late Stage Analyt Dev, San Francisco, CA 94080 USA
[7] Hlth Canada, Biol Res Ctr, Ottawa, ON K1A 0L2, Canada
[8] Medarex Inc, Analyt Dev & Formulat Dev, Bloomsbury, NJ 08804 USA
[9] Pfizer, Pfizer Global Res & Dev, Global Biol, Analyt Res & Dev, Chesterfield, MO 63017 USA
[10] Pfizer, Pfizer Global Res & Dev, Prot Sci, Chesterfield, MO 63017 USA
[11] Seattle Genet Inc, Analyt Biochem & Formulat, Bothell, WA 98021 USA
[12] Syngenta Ltd, Bracknell RG42 6EY, Berks, England
[13] GlaxoSmithKline Inc, Pharmaceut Dev, Harlow CM, Essex, England
关键词
capillary electrophoresis; collaboration exercise; biopharmaceutical analysis; CE-SDS;
D O I
10.1365/s10337-006-0003-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An international project team (including members from US, Canada and UK) has been formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results from this exercise demonstrate the robustness of CE-SDS across eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology. Data generated from the analysis of a series of molecular weight markers showed very good precision with regards to relative migration time (RMT) both within and between organisations. The apparent molecular weight of bovine serum albumin (BSA) was measured with good precision to within approximately 2% RSD across the participants. A representative IgG sample showed similar results with regards to relative migration time of its 3 main components, IgG Light Chain, IgG Nonglycosylated Heavy Chain, and IgG Heavy Chain. Fractional peak area for each peak also showed good agreement, with less than 9% RSD for all peaks. This exercise will facilitate both increased regulatory and industrial opinion of CE for biopharmaceutical analysis.
引用
收藏
页码:359 / 368
页数:10
相关论文
共 36 条
  • [21] MA S, 2005, 18 INT S MICR BIOS N
  • [22] Manabe T, 1999, ELECTROPHORESIS, V20, P3116, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3116::AID-ELPS3116>3.0.CO
  • [23] 2-0
  • [24] HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS OF SDS-PROTEINS USING PULLULAN SOLUTION AS SEPARATION MATRIX
    NAKATANI, M
    SHIBUKAWA, A
    NAKAGAWA, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 672 (1-2) : 213 - 218
  • [25] A SIMPLIFIED ULTRASENSITIVE SILVER STAIN FOR DETECTING PROTEINS IN POLYACRYLAMIDE GELS
    OAKLEY, BR
    KIRSCH, DR
    MORRIS, NR
    [J]. ANALYTICAL BIOCHEMISTRY, 1980, 105 (02) : 361 - 363
  • [26] Patrick JS, 2001, ELECTROPHORESIS, V22, P4179, DOI 10.1002/1522-2683(200111)22:19<4179::AID-ELPS4179>3.0.CO
  • [27] 2-8
  • [28] Schenerman MA, 2001, CHROMATOGRAPHIA, V53, pS66
  • [29] Schmerr MJ, 1997, J CHROMATOGR B, V697, P223
  • [30] Shen YF, 2002, ELECTROPHORESIS, V23, P3106, DOI 10.1002/1522-2683(200209)23:18<3106::AID-ELPS3106>3.0.CO