Comparison of cystatin C, creatinine and creatinine clearance vs. GFR for detection of renal failure in renal transplant patients

被引:20
作者
Daniel, JP
Chantrel, F
Offner, M
Moulin, B
Hannedouche, T
机构
[1] Hop E Muller, Pharm & Steriliz Dept, F-68070 Mulhouse, France
[2] Hop Univ Strasbourg, Dept Nephrol, Strasbourg, France
[3] Fac Med Strasbourg, Dept Biochem, F-67000 Strasbourg, France
关键词
creatinine; cystatin C; glomerular filtration rate; inulin clearance; renal transplant; ROC; AURC; best fits; Cockcroft & Gault; correlation; cut-off; kidney function; marker; predictive; sensitivity; specificity;
D O I
10.1081/JDI-120039523
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Serum cystatin C (Scyst) has been suggested as an alternative index of glomerular filtration rate (GFR) and could be useful in renal transplant patients. Methods: In a 60-subject cohort (40+/-12 years old), we compared the simultaneous measurements of Scyst, serum creatinine (Screat), creatinine clearance (Ccreat), Cockcroft and Gault's estimated clearance (Ccg) and GFR measured using inulin clearance (Cin). Receiver operating characteristic (ROC) analysis was performed using two Cin cut-off (60 and 90 mL/min/1.73 m(2)). Results: A significant correlation was found among Cin on one hand and 1/Scyst, Ccreat, 1/Screat and Ccg on the other hand. Best fits (sensitivity/specificity) at 90 mL/min/1.73 m(2) were 1.18 mg/L (0.72/0.80) for Scyst, 1.32 mg/dL (0.67/0.90) for Screat, 77 mL/min (0.80/0.70) for Ccg and 104 mL/min (0.88/0.80) for Ccreat. The areas under the ROC curves were not significantly different. Conclusions: This study provides cut-off values for Screat and Cc for detection of renal failure in renal transplant patients. However, the results also suggest that Scyst is not a more sensitive marker than Screat or Ccg for detecting renal failure in renal transplant patients.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 20 条
[1]  
Bökenkamp A, 1999, CLIN CHEM, V45, P1866
[2]  
Chantrel F, 2000, CLIN NEPHROL, V54, P374
[3]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[4]   Application of newer clearance techniques for the determination of glomerular filtration rate [J].
Gaspari, F ;
Perico, N ;
Remuzzi, G .
CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 1998, 7 (06) :675-680
[5]  
GRUBB A, 1992, CLIN NEPHROL, V38, pS20
[6]   Cystatin C - an accurate marker of glomerular filtration rate after renal transplantation? [J].
Herget-Rosenthal, S ;
Trabold, S ;
Huesing, J ;
Heemann, U ;
Philipp, T ;
Kribben, A .
TRANSPLANT INTERNATIONAL, 2000, 13 (04) :285-289
[7]   CREATININE ASSAY BY A REACTION-KINETIC PRINCIPLE [J].
LARSEN, K .
CLINICA CHIMICA ACTA, 1972, 41 (01) :209-&
[8]  
Laterza OF, 2002, CLIN CHEM, V48, P2297
[9]  
Le Bricon T, 1999, CLIN CHEM, V45, P2243
[10]  
Le Bricon T, 2000, CLIN CHEM, V46, P1206