Measuring Rapid Enzymatic Kinetics by Electrochemical Method in Droplet-Based Microfluidic Devices with Pneumatic Valves

被引:115
作者
Han, Zuoyan [1 ]
Li, Wentao [2 ]
Huang, Yanyi [2 ]
Zheng, Bo [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Chem, Shatin, Hong Kong, Peoples R China
[2] Peking Univ, Coll Engn, Dept Adv Mat & Nanotechnol, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
X-RAY-SCATTERING; HYDROGEN-PEROXIDE; MECHANISM; SYSTEMS; CHIP; ELECTROPORATION; NANOLITERS; ELECTRODES; CATALASES; OXIDATION;
D O I
10.1021/ac900811y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a droplet-based microfluidic chip with pneumatic valves for measuring millisecond enzyme kinetics using amperometric detection method. Aqueous streams containing reactants were injected to an oil flow to form droplets, and each droplet represented one microreactor. Pneumatic valves were used to control the moving distance and in turn the reaction time of the droplets. The reaction time was also fine-tuned by varying the flow rate of the droplets in microchannels. A complete Michaelis-Menten kinetics of catalase was successfully measured by amperometric method in a single-run experiment, and the total consumption of reagents was less than 50 mu L In the current experiment, the best time resolution was about 0.05 s, and the reaction time measured was from 0.05 to 25 s. This microfluidic system is applicable to many biochemical reactions, as long as one of the reactants or products is electrochemically active. With appropriate quenching method at the outlet, various detection methods can be integrated into the microfluidic system, further extending the application of the combination of pneumatic valves and droplets in microchannels.
引用
收藏
页码:5840 / 5845
页数:6
相关论文
共 36 条
[1]   Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets [J].
Bringer, MR ;
Gerdts, CJ ;
Song, H ;
Tice, JD ;
Ismagilov, RF .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2004, 362 (1818) :1087-1104
[2]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[3]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326
[4]   KINETIC CONSEQUENCES OF THE REMOVAL OF A DISULFIDE BRIDGE ON THE FOLDING OF HEN LYSOZYME [J].
EYLES, SJ ;
RADFORD, SE ;
ROBINSON, CV ;
DOBSON, CM .
BIOCHEMISTRY, 1994, 33 (44) :13038-13048
[5]   Formation of droplets and bubbles in a microfluidic T-junction - scaling and mechanism of break-up [J].
Garstecki, P ;
Fuerstman, MJ ;
Stone, HA ;
Whitesides, GM .
LAB ON A CHIP, 2006, 6 (03) :437-446
[6]   Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorption-controlled mechanism [J].
Hall, SB ;
Khudaish, EA ;
Hart, AL .
ELECTROCHIMICA ACTA, 1998, 43 (5-6) :579-588
[7]   An agar-based silver|silver chloride reference electrode for use in micro-electrochemistry [J].
Hassel, AW ;
Fushimi, K ;
Seo, M .
ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (05) :180-183
[8]   Microdroplets: A sea of applications? [J].
Huebner, Ansgar ;
Sharma, Sanjiv ;
Srisa-Art, Monpichar ;
Hollfelder, Florian ;
Edel, Joshua B. ;
deMello, Andrew J. .
LAB ON A CHIP, 2008, 8 (08) :1244-1254
[9]   Stopped-flow kinetic investigations of conformational changes of pig kidney Na+,K+-ATPase [J].
Kane, DJ ;
Fendler, K ;
Grell, E ;
Bamberg, E ;
Taniguchi, K ;
Froehlich, JP ;
Clarke, RJ .
BIOCHEMISTRY, 1997, 36 (43) :13406-13420
[10]   FOLDING AND STABILITY OF A TRYPTOPHAN-CONTAINING MUTANT OF UBIQUITIN [J].
KHORASANIZADEH, S ;
PETERS, ID ;
BUTT, TR ;
RODER, H .
BIOCHEMISTRY, 1993, 32 (27) :7054-7063