Computation and visualization of three-dimensional soft tissue motion in the orbit

被引:55
作者
Abràmoff, MD
Viergever, MA
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Vrije Univ Amsterdam, Univ Hosp, Dept Ophthalmol, NL-1081 HV Amsterdam, Netherlands
关键词
cinematic MRI; multimodality visualization; optical flow; orbit;
D O I
10.1109/TMI.2002.1000254
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This work presents a method to measure the soft tissue motion in three dimensions in the orbit during gaze. It has been shown that two-dimensional (2-D) quantification of soft tissue motion in the orbit is effective in the study of orbital anatomy and motion disorders [1]. However, soft tissue motion is a three-dimensional (3-D) phenomenon and part of the kinematics is lost in any 2-D measurement. Therefore, T1-weighted magnetic resonance (MR) imaging volume sequences are acquired during gaze and soft tissue motion is quantified using a generalization of the Lucas and Kanade optical now algorithm to three dimensions. New techniques have been developed for visualizing the 3-D flow field as a series of color-texture mapped 2-D slices or as a combination of volume rendering for display of the anatomy and scintillation rendering for the display of the motion field. We have studied the performance of the algorithm on four-dimensional volume sequences of synthetic motion, simulated motion of a static object imaged by MR, an MR-imaged rotating object and MR-imaged motion in the human orbit during gaze. The accuracy of the analysis is sufficient to characterize motion in the orbit and scintillation rendering is an effective visualization technique for 3-D motion in the orbit.
引用
收藏
页码:296 / 304
页数:9
相关论文
共 36 条
[1]  
Abràmoff MD, 2000, INVEST OPHTH VIS SCI, V41, P3256
[2]  
Abràmoff MD, 2000, IEEE T MED IMAGING, V19, P986, DOI 10.1109/42.887614
[3]  
ABRAMOFF MD, 2000, INVESTIGAT OPTHAL VI, V41, P738
[4]   A NEW APPROACH TO STUDY CARDIAC MOTION - THE OPTICAL-FLOW OF CINE MR IMAGES [J].
AMARTUR, SC ;
VESSELLE, HJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :59-67
[5]   Measuring blood flow by nontriggered 2D phase-contrast MR angiography [J].
Bakker, CJG ;
Hartkamp, MJ ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :609-614
[6]  
BANKS DC, 1994, COMPUT GRAPH, V28, P327
[7]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[8]  
Cabral B, 1993, P 20 ANN C COMP GRAP, P263, DOI DOI 10.1145/166117.166151
[9]  
CASTLEMAN K. R., 1996, Digital image processing