Measuring blood flow by nontriggered 2D phase-contrast MR angiography

被引:70
作者
Bakker, CJG
Hartkamp, MJ
Mali, WPTM
机构
[1] Department of Radiology, University Hospital Utrecht, 3584CX, Utrecht
关键词
magnetic resonance; magnetic resonance angiography; flow quantification; carotid artery; popliteal artery;
D O I
10.1016/0730-725X(96)00092-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was done to assess the validity of nontriggered 2D phase contrast MR angiography for measuring blood flow in human arteries and veins. Volume flow in the popliteal and internal carotid arteries was measured by nontriggered and triggered 2DPC in 13 normal volunteers (mean age 27, range 18-46). Parameter selection was guided by previous phantom experiments. Results were compared by linear regression analysis, Measurement error was determined by one-way analysis of variance of repeated measurements, In the internal carotid arteries, good agreement was found between the volume flow, Q, as determined by a triggered measurement and a nontriggered measurement: Qntr=0.988 (+/-0.006) Qtr, r=0.98, SEE=0.16 ml/s. The estimated measurement errors of both techniques were of the same order: 0.27 vs. 0.31 ml/s. Substantial deviations between triggered and nontriggered 2DPC were found in the popliteal artery: Qntr=0.827(+/-0.028) Qtr, r=0.97, SEE=0.12 ml/s. The estimated measurement error of nontriggered 2DPC turned out to be twice as large as of triggered 2DPC here: 0.22 vs, 0.13 ml/s. We believe that nontriggered 2DPC is a valid technique for measuring blood flow in stationary vessels with weakly pulsatile flow, but merely provides a rough estimation for strongly pulsatile flow, In its current implementation, nontriggered 2DPC provides the data in 40 s, whereas triggered 2DPC requires 3-4 min, and offers additional time savings with regard to patient preparation and data processing.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 10 条
[1]  
Armitage P, 1987, Statistical methods in medical research, V2nd
[2]   Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation [J].
Bakker, CJG ;
Kouwenhoven, M ;
Hartkamp, MJ ;
Hoogeveen, RM ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1995, 13 (07) :959-965
[3]   BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING [J].
BOGREN, HG ;
BUONOCORE, MH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) :119-130
[4]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[5]   COMPARISON OF CEREBRAL-ARTERY BLOOD-FLOW MEASUREMENTS WITH GATED CINE AND UNGATED PHASE-CONTRAST TECHNIQUES [J].
ENZMANN, DR ;
MARKS, MP ;
PELC, NJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05) :705-712
[6]   ANALYSIS OF MR PHASE-CONTRAST MEASUREMENTS OF PULSATILE VELOCITY WAVE-FORMS [J].
HANGIANDREOU, NJ ;
ROSSMAN, PJ ;
RIEDERER, SJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :387-394
[7]   NONTRIGGERED MAGNETIC-RESONANCE VELOCITY-MEASUREMENT OF THE TIME-AVERAGE OF PULSATILE VELOCITY [J].
HOFMAN, MBM ;
KOUWENHOVEN, M ;
SPRENGER, M ;
VANROSSUM, AC ;
VALK, J ;
WESTERHOF, N .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) :648-655
[8]   VELOCITY AND FLOW QUANTITATION IN THE SUPERIOR SAGITTAL SINUS WITH UNGATED AND CINE (GATED) PHASE-CONTRAST MR-IMAGING [J].
JORDAN, JE ;
PELC, NJ ;
ENZMANN, DR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01) :25-28
[9]   BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE [J].
NAYLER, GL ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :715-722
[10]   THE MEASUREMENT OF TIME-AVERAGED FLOW BY MAGNETIC-RESONANCE-IMAGING USING CONTINUOUS ACQUISITION IN THE CAROTID ARTERIES AND ITS COMPARISON WITH DOPPLER ULTRASOUND [J].
TARNAWSKI, M ;
PADAYACHEE, S ;
WEST, DJ ;
GRAVES, MJ ;
AYTON, VT ;
TAYLOR, MG ;
SMITH, MA .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (01) :27-36