Adaptive correction of imaging plane position in segmented K-space cine cardiac MRI

被引:18
作者
Chuang, ML [1 ]
Chen, MH [1 ]
Khasgiwala, VC [1 ]
McConnell, MV [1 ]
Edelman, RR [1 ]
Manning, WJ [1 ]
机构
[1] BETH ISRAEL HOSP,CHARLES A DANA RES INST,BOSTON,MA 02215
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 05期
关键词
heart; MR; left ventricular function; navigator echo; myocardium;
D O I
10.1002/jmri.1880070507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variability among breath-holds frequently produces registration errors, a situation that may contribute to reproducibility error in anatomic indices, A navigator-echo-based method for real-time prospective correction of imaging slice level was applied to breath-hold cine cardiac imaging of 13 subjects. Repeat acquisitions with correction in the cardiac short-axis orientation showed significantly improved reproducibility in fractional area change and endocardial centroid location as compared with conventional noncorrected methods.
引用
收藏
页码:811 / 814
页数:4
相关论文
共 10 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE [J].
BUSER, PT ;
AUFFERMANN, W ;
HOLT, WW ;
WAGNER, S ;
KIRCHER, B ;
WOLFE, C ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1294-1300
[3]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[4]   Coronary arteries: Three-dimensional MR imaging with retrospective respiratory gating [J].
Li, DB ;
Kaushikkar, S ;
Haacke, EM ;
Woodard, PK ;
Dhawale, PJ ;
Kroeker, RM ;
Laub, G ;
Kuginuki, Y ;
Gutierrez, FR .
RADIOLOGY, 1996, 201 (03) :857-863
[5]   Prospective adaptive navigator correction for breath-hold MR coronary angiography [J].
McConnell, MV ;
Khasgiwala, VC ;
Savord, BJ ;
Chen, MH ;
Chuang, ML ;
Edelman, RR ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :148-152
[6]   REAL-TIME MOTION DETECTION IN SPIRAL MRI USING NAVIGATORS [J].
SACHS, TS ;
MEYER, CH ;
HU, BS ;
KOHLI, J ;
NISHIMURA, DG ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :639-645
[7]   EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING [J].
SAKUMA, H ;
FUJITA, N ;
FOO, TKF ;
CAPUTO, GR ;
NELSON, SJ ;
HARTIALA, J ;
SHIMAKAWA, A ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :377-380
[8]   NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING [J].
SEMELKA, RC ;
TOMEI, E ;
WAGNER, S ;
MAYO, J ;
KONDO, C ;
SUZUKI, J ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1990, 174 (03) :763-768
[9]   CORONARY MRI WITH A RESPIRATORY FEEDBACK MONITOR - THE 2D IMAGING CASE [J].
WANG, Y ;
CHRISTY, PS ;
KOROSEC, FR ;
ALLEY, MT ;
GRIST, TM ;
POLZIN, JA ;
MISTRETTA, CA .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :116-121
[10]   RESPIRATORY MOTION OF THE HEART - KINEMATICS AND THE IMPLICATIONS FOR THE SPATIAL-RESOLUTION IN CORONARY IMAGING [J].
WANG, Y ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :713-719