Rapid automated cell quantification on HIV microfluidic devices

被引:65
作者
Alyassin, Mohamad A. [1 ,2 ]
Moon, SangJun [1 ]
Keles, Hasan O. [1 ]
Manzur, Fahim [1 ]
Lin, Richard L. [1 ]
Haeggstrom, Edward [3 ]
Kuritzkes, Daniel R. [4 ]
Demirci, Utkan [1 ,5 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Bioacoust MEMS Med Lab,Ctr Biomed Engn,Dept Med, Cambridge, MA 02139 USA
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[3] Univ Helsinki, Dept Phys, FIN-00014 Helsinki, Finland
[4] Harvard Univ, Brigham & Womens Hosp, Sch Med, Sect Retroviral Therapeut, Boston, MA 02115 USA
[5] Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
D O I
10.1039/b911882a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lab-chip device analysis often requires high throughput quantification of fluorescent cell images, obtained under different conditions of fluorescent intensity, illumination, focal depth, and optical magnification. Many laboratories still use manual counting - a tedious, expensive process prone to inter-observer variability. The manual counting process can be automated for fast and precise data gathering and reduced manual bias. We present a method to segment and count cells in microfluidic chips that are labeled with a single stain, or multiple stains, using image analysis techniques in Matlab and discuss its advantages over manual counting. Microfluidic based cell capturing devices for HIV monitoring were used to validate our method. Captured CD4(+) CD3(+) T lymphocytes were stained with DAPI, AF488-anti CD4, and AF647-anti CD3 for cell identification. Altogether 4788 (76 x 3 x 21) gray color images were obtained from devices using discarded 10 HIV infected patient whole blood samples (21 devices). We observed that the automatic method performs similarly to manual counting for a small number of cells. However, automated counting is more accurate and more than 100 times faster than manual counting for multiple-color stained cells, especially when large numbers of cells need to be quantified (>500 cells). The algorithm is fully automatic for subsequent microscope images that cover the full device area. It accounts for problems that generally occur in fluorescent lab-chip cell images such as: uneven background, overlapping cell images and cell detection with multiple stains. This method can be used in laboratories to save time and effort, and to increase cell counting accuracy of lab-chip devices for various applications, such as circulating tumor cell detection, cell detection in biosensors, and HIV monitoring devices, i.e. CD4 counts.
引用
收藏
页码:3364 / 3369
页数:6
相关论文
共 26 条
  • [1] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [2] [Anonymous], 2006, Digital Image Processing
  • [3] ANORAGANINGRUM D, 1999, ICIAP 99
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Cheng XH, 2007, JAIDS-J ACQ IMM DEF, V45, P257
  • [6] DIRUBETO C, 2000, P INT C PATT REC, V3
  • [7] DOUGHERTY ER, 1992, INTRO MORPHOLOGICAL
  • [8] A microfabricated fluorescence-activated cell sorter
    Fu, AY
    Spence, C
    Scherer, A
    Arnold, FH
    Quake, SR
    [J]. NATURE BIOTECHNOLOGY, 1999, 17 (11) : 1109 - 1111
  • [9] Glory E, 2004, LECT NOTES COMPUT SC, V3212, P84
  • [10] JEACOCKE MB, 1994, P 1994 2 AUSTR NZ C