Ionic liquids as mobile phase additives in high-performance liquid chromatography with electrochemical detection: Application to the determination of heterocyclic aromatic amines in meat-based infant foods

被引:52
作者
Martin-Calero, Aurora [1 ]
Pino, Veronica [1 ]
Ayala, Juan H. [1 ]
Gonzalez, Venerando [1 ]
Afonso, Ana M. [1 ]
机构
[1] Univ La Laguna, Dept Analyt Chem Nutr & Food Sci, San Cristobal la Laguna 38205, Spain
关键词
Heterocyclic aromatic amines; Ionic liquids; High-performance liquid chromatography; Electrochemical detection; Meat-based infant foods; MICROWAVE-ASSISTED EXTRACTION; TANDEM MASS-SPECTROMETRY; MICROEXTRACTION; HYDROCARBONS; HPLC;
D O I
10.1016/j.talanta.2009.04.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The beneficial effects of several ionic liquids (ILs) as mobile phase additives in high-performance liquid chromatography with electrochemical detection for the determination of six heterocyclic aromatic amines (HAs) have been evaluated for first-time. The studied ionic liquids were 1-butyl-3-methylimidazolium tetrafluoroborate (BMIm-BF4), 1-hexyl-3-methylimidazolium tetrafluoroborate (HMIm-BF4) and 1-methyl-3-octylimidazolium tetrafluoroborate (MOIm-BF4). Several chromatographic parameters have been evaluated in the presence or absence of ILs, or using ammonium acetate as the most common mobile phase additive, with three different C18 stationary phases. The effect of the acetonitrile content was also addressed. In general, best resolution, lower peak-widths (up to 72.1% lower) and lower retention factors are obtained when using ILs rather than ammonium acetate as mobile phase additives. The main improvement was obtained in the baseline noise, being 360% less noisy for BMIm-BF4, 310% for HMIm-BF4, and 227% for MOIm-BF4, when compared to ammonium acetate at +1000 mV. Different chromatographic methods using the best conditions for each IL were also evaluated and compared. Finally, the best chromatographic conditions using 1 mM of BMIm-BF4 as mobile phase additive, the Nova-Pak (R) C18 column, 19% (v/v) of acetonitrile content in the mobile phase, and +1000 mV in the ECD, have been applied for the chromatographic analysis of six HAs contained in meat-based infant foods. The whole extraction method of meat-based infant foods using focused microwave-assisted extraction and solid-phase extraction has also been optimized. Extraction efficiencies up to 89% and detection limits ranged between 9.30 and 0.165 ng g(-1) have been obtained under optimized conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:590 / 597
页数:8
相关论文
共 31 条
[1]   Immobilized ionic liquids as high-selectivity/high-temperature/high-stability gas chromatography stationary phases [J].
Anderson, JL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6453-6462
[2]  
[Anonymous], 1998, ANALYST
[3]   Evaluation of reversed-phase columns for the analysis of heterocyclic aromatic amines by liquid chromatography -: electrospray mass spectrometry [J].
Barceló-Barrachina, E ;
Moyano, E ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (01) :45-59
[4]   Analysis of heterocyclic amines in chicken by liquid chromatography with electrochemical detection [J].
Bermudo, E ;
Ruiz-Calero, V ;
Puignou, L ;
Galceran, MT .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :83-90
[5]   Use of the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate in countercurrent chromatography [J].
Berthod, A ;
Carda-Broch, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) :168-177
[6]   Validation of an ion-pair liquid chromatography-electrospray-tandem mass spectrometry method for the determination of heterocyclic aromatic amines in meat-based infant foods [J].
Calbiani, F. ;
Careri, M. ;
Elviri, L. ;
Mangia, A. ;
Zagnoni, I. .
FOOD ADDITIVES AND CONTAMINANTS, 2007, 24 (08) :833-841
[7]   Experimental design optimization of solid-phase microextraction conditions for the determination of heterocyclic aromatic amines by high-performance liquid chromatography [J].
Cárdenes, L ;
Martín-Calero, A ;
Ayala, JH ;
González, V ;
Afonso, AM .
ANALYTICAL LETTERS, 2006, 39 (02) :405-423
[8]   Effect of mobile phase composition on the retention of selected alkaloids in reversed-phase liquid chromatography with chaotropic salts [J].
Flieger, J. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1175 (02) :207-216
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF 10 HETEROCYCLIC AROMATIC-AMINES WITH ELECTROCHEMICAL DETECTION [J].
GALCERAN, MT ;
PAIS, P ;
PUIGNOU, L .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (01) :101-110
[10]   Comparison of the performance of a few packing materials designed to minimize the thermodynamic band tailing of basic compounds in reversed-phase liquid chromatography [J].
Gritti, Fabrice ;
Perdu, Cecile ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1180 (1-2) :73-89