Automated cardiac flow measurement by digital colour Doppler echocardiography

被引:1
作者
Shiota, T [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med F15, Cleveland, OH 44195 USA
关键词
D O I
10.1136/heart.88.3.211
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Quantification of cardiac flow volumes, such as stroke volumes and cardiac outputs, has had a major impact on the management of patients with cardiac diseases.
引用
收藏
页码:211 / 212
页数:2
相关论文
共 11 条
  • [1] Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study
    Aida, S
    Shiota, T
    Tsujino, H
    Sahn, DJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (09) : 874 - 881
  • [2] THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS
    FISHER, DC
    SAHN, DJ
    FRIEDMAN, MJ
    LARSON, D
    VALDESCRUZ, LM
    HOROWITZ, S
    GOLDBERG, SJ
    ALLEN, HD
    [J]. CIRCULATION, 1983, 67 (02) : 370 - 376
  • [3] EVALUATION OF PULMONARY AND SYSTEMIC BLOOD-FLOW BY TWO-DIMENSIONAL DOPPLER ECHOCARDIOGRAPHY USING FAST FOURIER-TRANSFORM SPECTRAL-ANALYSIS
    GOLDBERG, SJ
    SAHN, DJ
    ALLEN, HD
    VALDESCRUZ, LM
    HOENECKE, H
    CARNAHAN, Y
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1982, 50 (06) : 1394 - 1400
  • [4] NON-INVASIVE EVALUATION OF THE RATIO OF PULMONARY TO SYSTEMIC FLOW IN ATRIAL SEPTAL-DEFECT BY DUPLEX DOPPLER ECHOCARDIOGRAPHY
    KITABATAKE, A
    INOUE, M
    ASAO, M
    ITO, H
    MASUYAMA, T
    TANOUCHI, J
    MORITA, T
    HORI, M
    YOSHIMA, H
    OHNISHI, K
    ABE, H
    [J]. CIRCULATION, 1984, 69 (01) : 73 - 79
  • [5] Validation of a digital color Doppler flow measurement method for pulmonary regurgitant volumes and regurgitant fractions in an in vitro model and in a chronic animal model of postoperative repaired tetralogy of Fallot
    Mori, Y
    Irvine, T
    Jones, M
    Rusk, RA
    Pham, Q
    Kenny, A
    Sahn, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 632 - 640
  • [6] Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model
    Shiota, T
    Jones, M
    Aida, S
    Chikada, M
    Tsujino, H
    El-Kadi, T
    Sahn, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) : 587 - 593
  • [7] Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: An animal study with quantified chronic aortic regurgitation
    Shiota, T
    Jones, M
    Aida, S
    Tsujino, H
    Yamada, I
    Delabays, A
    Pandian, NG
    Sahn, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 834 - 842
  • [8] Sun JP, 1997, CIRCULATION, V95, P932
  • [9] Quantification of mitral regurgitation by automated cardiac output measurement: Experimental and clinical validation
    Sun, JP
    Yang, XS
    Qin, JX
    Greenberg, NL
    Zhou, JH
    Vazquez, CJ
    Griffin, BP
    Stewart, WJ
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) : 1074 - 1082
  • [10] Tsujino H, 1995, J Am Soc Echocardiogr, V8, P621, DOI 10.1016/S0894-7317(05)80375-X