Radiation doses during pediatric radiofrequency catheter ablation procedures

被引:17
作者
Geise, RA [1 ]
Peters, NE [1 ]
Dunnigan, A [1 ]
Milstein, S [1 ]
机构
[1] MINNEAPOLIS CARDIOL ASSOCIATES,MINNEAPOLIS,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1996年 / 19卷 / 11期
关键词
radiation dose; ablation; pediatric cardiology;
D O I
10.1111/j.1540-8159.1996.tb03187.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Because RF catheter ablation procedures may be lengthy and are commonly performed in young patients, concern has arisen about radiation dose in this group of patients. This article investigates radiation doses in pediatric patients undergoing RF catheter ablation. Standard fluoroscopic equipment used for diagnostic electrophysiological catheterization studies is technologically capable of dose rates as high as 90 milligray (mGy) per minute to skin and adjacent lung and 260 mGy/min to vertebral bone. Dose rates of this magnitude when used for extended periods of time have been known to cause erythema, pneumonitis, and retardation of bone growth. We measured skin dose rates of nine pediatric patients undergoing RF catheter ablation for tachycardia and calculated doses to the skin using standard dosimetric methods. Fluoroscopic techniques and equipment were studied using a patient simulating phantom. Overlap of fluoroscopic fields was checked using radiotherapy portal verification film, and regions in which doses overlapped from multiple angle exposures were verified using a treatment planning computer. Patient skin dose rates ranged from 6.2-49 m Gy/min for patients ranging in age from 2-20 years. Maxim um skin doses ranged from 0.09-2.35 Gy Our data demonstrate the need to directly measure dose rates for individual fluoroscopic equipment and procedural techniques in order to determine whether limitations need to be set for procedural times.
引用
收藏
页码:1605 / 1611
页数:7
相关论文
共 13 条
[1]   RADIATION EXPOSURE DURING RADIOFREQUENCY CATHETER ABLATION OF ACCESSORY ATRIOVENTRICULAR CONNECTIONS [J].
CALKINS, H ;
NIKLASON, L ;
SOUSA, J ;
ELATASSI, R ;
LANGBERG, J ;
MORADY, F .
CIRCULATION, 1991, 84 (06) :2376-2382
[2]   RADIATION EXPOSURE TO PATIENTS UNDERGOING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
CASCADE, PN ;
PETERSON, LE ;
WAJSZCZUK, WJ ;
MANTEL, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (09) :996-997
[3]   RADIOFREQUENCY CATHETER ABLATION OF INCESSANT, MEDICALLY RESISTANT SUPRAVENTRICULAR TACHYCARDIA IN INFANTS AND SMALL CHILDREN [J].
CASE, CL ;
GILLETTE, PC ;
OSLIZLOK, PC ;
KNICK, BJ ;
BLAIR, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (06) :1405-1410
[4]   A SURVEY OF FILMS FOR USE AS DOSIMETERS IN INTERVENTIONAL RADIOLOGY [J].
FAJARDO, LC ;
GEISE, RA ;
RITENOUR, ER .
HEALTH PHYSICS, 1995, 68 (04) :595-599
[5]   RADIATION-DOSES AND SOMATIC RISK TO PATIENTS DURING CARDIAC RADIOLOGICAL PROCEDURES [J].
FAULKNER, K ;
LOVE, HG ;
SWEENEY, JK ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (700) :359-363
[6]   CURATIVE PERCUTANEOUS CATHETER ABLATION USING RADIOFREQUENCY ENERGY FOR ACCESSORY PATHWAYS IN ALL LOCATIONS - RESULTS IN 100 CONSECUTIVE PATIENTS [J].
LESH, MD ;
VANHARE, GF ;
SCHAMP, DJ ;
CHIEN, W ;
LEE, MA ;
GRIFFIN, JC ;
LANGBERG, JJ ;
COHEN, TJ ;
LURIE, KG ;
SCHEINMAN, MM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (06) :1303-1309
[7]  
METTLER FA, 1985, MED EFFECTS IONIZING, P161
[8]  
PETERSON R, 1980, CROSS SECTIONAL APPR, P92
[9]  
REUTER FG, 1978, CIRCULATION, V58, P134
[10]  
SELLERS TD, 1992, PACE, V15, P582