Determination of albendazole and its main metabolites in ovine plasma by liquid chromatography with dialysis as an integrated sample preparation technique

被引:28
作者
Chiap, P
Evrard, B
Bimazubute, MA
de Tullio, P
Hubert, P
Delattre, L
Crommen, J
机构
[1] CHU Sart Tilman, Dept Pharmaceut Analyt Chem, Inst Pharm, Univ Liege, B-4000 Liege 1, Belgium
[2] CHU Sart Tilman, Dept Pharmaceut Technol, Inst Pharm, Univ Liege, B-4000 Liege, Belgium
[3] CHU Sart Tilman, Med Chem Lab, Inst Pharm, Univ Liege, B-4000 Liege 1, Belgium
关键词
sample preparation; dialysis; gradient elution; computer simulation; albendazole; benzimidazoles;
D O I
10.1016/S0021-9673(99)00938-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Albendazole is a benzimidazole derivative with a broad-spectrum activity against human and animal helminth parasites. Ln order to determine the main pharmacokinetic parameters in sheep after oral and intravenous administration of a new formulation of albendazole (an aqueous solution), a fully automated method was developed for the determination of this drug and its main metabolites, albendazole sulfoxide (active metabolite) and sulfone in ovine plasma. This method involves dialysis as purification step, followed by enrichment of the dialysate on a precolumn and liquid chromatography (LC), All sample handling operations were executed automatically by means of an ASTED XL system. After conditioning of the trace enrichment column (TEC) packed with octadecyl silica with pH 6.0 phosphate buffer containing sodium azide, the plasma sample, in which a protein releasing reagent(1 M HCl) containing Triton X-100 was automatically added, was loaded in the donor channel and dialysed on a cellulose acetate membrane in the static-pulsed mode. The dialysis liquid consisted of pH 2.5 phosphate buffer. By rotation of a switching valve, the analytes were eluted from the TEC in the back-flush mode by the LC mobile phase and transferred to the analytical column, packed with octyl silica, The chromatographic separation was performed at 35 degrees C and the analytes were monitored photometrically at 295 nm. Due to the differences in hydrophobic character between albendazole and its metabolites, a gradient elution was applied. The mobile phase consisted of a mixture of acetonitrile and pH 6.0 phosphate buffer. The proportion of organic modifier was increased from 10.0 to 50.1% in 12.30 min, then from 50.1 to 66.9% in 1.70 min. First, the gradient conditions and the temperature were optimised for the LC separation using the DryLab software. Then, the influence of some parameters of the dialysis process on analyte recovery was investigated. Finally, the method developed was validated. The mean recoveries for albendazole and its metabolites were about 70 and 65%, respectively. The Limits of quantification for albendazole and its metabolites were 10 and 7.5 ng/ml, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:121 / 134
页数:14
相关论文
共 30 条
[1]   AUTOMATED-ANALYSIS OF OXOLINIC ACID AND FLUMEQUINE IN SALMON WHOLE-BLOOD AND PLASMA USING DIALYSIS COMBINED WITH TRACE ENRICHMENT AS ONLINE SAMPLE PREPARATION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
AGASOSTER, T ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :171-179
[2]  
Alvinerie M, 1984, J Pharm Biomed Anal, V2, P73, DOI 10.1016/0731-7085(84)80091-6
[3]   Enantioselective determination of oxprenolol in human plasma using dialysis coupled on-line to reversed-phase chiral liquid chromatography [J].
Ceccato, A ;
Toussaint, B ;
Chiap, P ;
Hubert, P ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) :1365-1374
[4]   Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection [J].
Ceccato, A ;
Chiap, P ;
Hubert, P ;
Toussaint, B ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :351-360
[5]  
CHAPUZET E, 1998, STP PHARM PRATIQUES, V8, P81
[6]  
Chapuzet E., 1997, STP Pharma Pratiques, V7, P169
[7]   Validation of an automated method for the liquid chromatographic determination of atenolol in plasma: application of a new validation protocol [J].
Chiap, P ;
Hubert, P ;
Boulanger, B ;
Crommen, J .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :227-238
[8]  
CHIAP P, UNPUB J CHROMATOGR B
[9]   Development of an assay for the simultaneous determination of sildenafil (Viagra) and its metabolite (UK-103,320) using automated sequential trace enrichment of dialysates and high-performance liquid chromatography [J].
Cooper, JDH ;
Muirhead, DC ;
Taylor, JE ;
Baker, PR .
JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01) :87-95
[10]   Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development - I. Application to 14 different samples using computer simulation [J].
Dolan, JW ;
Snyder, LR ;
Djordjevic, NM ;
Hill, DW ;
Saunders, DL ;
Van Heukelem, L ;
Waeghe, TJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :1-31