Voltammetric analysis of europium at screen-printed electrodes modified with salicylamide self-assembled on mesoporous silica

被引:20
作者
Yantasee, Wassana [1 ]
Fryxell, Glen E. [1 ]
Lin, Yuehe [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
关键词
D O I
10.1039/b609211j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mercury-free sensors for europium (Eu3+) assay based on the chemical modification of screen-printed carbon electrodes (SPCEs) with self-assembled salicylamide on mesoporous silica (Sal-SAMMS) have been developed. The preconcentration of Eu3+ at SAMMS-based sensors utilizes the binding affinity of the salicylamide and Eu3+, accomplished at open circuit potential without electrolyte and solution de-gassing. Optimal Eu detection was obtained after 3 - 5 min preconcentration in Eu solution (pH 2 - 6), electrolysis at -0.9 V for 60 s in a new medium (0.1 - 0.2 M NH4Cl, pH 3.5), followed by a square-wave voltammetric detection of Eu in the same electrolyte. Attributed to the strong covalent bonding of the functional groups on mesoporous silica and silane cross-linking, the SAMMS-modified SPCEs with a built-in 3-electrode system can be re-used for tens of measurements with minimal degradation, enabling the establishment of the calibration curve and lowering the costs. A linear calibration curve was found in the range of 75 to at least 500 ppb Eu3+ after 5 min preconcentration. The experimental detection limit was 10 ppb after 10 min preconcentration, which can be improved with increased preconcentration time. Reproducibility (% RSD) of 100 ppb Eu2+ was 10% for a single sensor and 10% for 5 sensors, which can be improved through the precision of sensor manufacturing, in which SAMMS modification can be made in-situ.
引用
收藏
页码:1342 / 1346
页数:5
相关论文
共 39 条
[1]   Synthesis of carbamoylphosphonate silanes for the selective sequestration of actinides [J].
Birnbaum, JC ;
Busche, B ;
Lin, YH ;
Shaw, WJ ;
Fryxell, GE .
CHEMICAL COMMUNICATIONS, 2002, (13) :1374-1375
[2]   Mercury separation and immobilization using self-assembled monolayers on mesoporous supports (SAMMS) [J].
Chen, XB ;
Feng, XD ;
Liu, J ;
Fryxell, GE ;
Gong, ML .
SEPARATION SCIENCE AND TECHNOLOGY, 1999, 34 (6-7) :1121-1132
[3]   Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis [J].
Choi, JY ;
Seo, K ;
Cho, SR ;
Oh, JR ;
Kahng, SH ;
Park, J .
ANALYTICA CHIMICA ACTA, 2001, 443 (02) :241-247
[4]   An environmental monitoring system for trace metals using stripping voltammetry [J].
Desmond, D ;
Lane, B ;
Alderman, J ;
Hill, M ;
Arrigan, DWM ;
Glennon, JD .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) :409-414
[5]   Functionalized monolayers on ordered mesoporous supports [J].
Feng, X ;
Fryxell, GE ;
Wang, LQ ;
Kim, AY ;
Liu, J ;
Kemner, KM .
SCIENCE, 1997, 276 (5314) :923-926
[6]   Electrochemistry of the aqueous europium(III)/europium(II) redox couple at conductive diamond electrodes [J].
Ferro, S ;
De Battisti, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 533 (1-2) :177-180
[7]   Design and synthesis of selective mesoporous anion traps [J].
Fryxell, GE ;
Liu, J ;
Hauser, TA ;
Nie, ZM ;
Ferris, KF ;
Mattigod, S ;
Gong, ML ;
Hallen, RT .
CHEMISTRY OF MATERIALS, 1999, 11 (08) :2148-2154
[8]   Lanthanide selective sorbents: self-assembled monolayers on mesoporous supports (SAMMS) [J].
Fryxell, GE ;
Wu, H ;
Lin, YH ;
Shaw, WJ ;
Birnbaum, JC ;
Linehan, JC ;
Nie, ZM ;
Kemner, K ;
Kelly, S .
JOURNAL OF MATERIALS CHEMISTRY, 2004, 14 (22) :3356-3363
[9]   Actinide sequestration using self-assembled monolayers on mesoporous supports [J].
Fryxell, GE ;
Lin, YH ;
Fiskum, S ;
Birnbaum, JC ;
Wu, H ;
Kemner, K ;
Kelly, S .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (05) :1324-1331
[10]  
Fryxell GE, 2002, STUD SURF SCI CATAL, V141, P583