Harmful azo colorants in leather - Determination based on their cleavage and extraction of corresponding carcinogenic aromatic amines using modern extraction techniques

被引:55
作者
Eskilsson, CS [1 ]
Davidsson, R [1 ]
Mathiasson, L [1 ]
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
supercritical fluid extraction; microwave-assisted extraction; extraction methods; amines; aromatic; azo dyes;
D O I
10.1016/S0021-9673(02)00323-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study concerns the possibilities of using microwave-assisted extraction (MAE) or supercritical fluid extraction (SFE) for detection of harmful azo colorants in leather. After degreasing of the leather sample with SFE there follows a reductive cleavage of the azo colorants to their corresponding aromatic an-dries in the MAE or SITE equipment. The aromatic amines are subsequently extracted using either MAE or SFE and then finally determined by liquid chromatography with diode-array detection. The results have been compared with recoveries obtained using the German DIN method 53316. This standard method, based on conventional solvent extraction, is used in several European countries. Overall much better recoveries were obtained using MAE or SFE. With both MAE and SFE the an-Line recoveries of spiked leather samples were generally above 50%. The average recoveries were 62% for MAE and 60% for SFE (solvent collection) compared to 24% with the DIN method. For genuine leather samples the recoveries decreased, especially for benzidine. In this case the average values for MAE, SFE and DIN were 54, 38 and 19%, respectively. The quantification limits in leather samples using MAE or SFE were below 1 mg/kg for all amines investigated. The within-lab oratory precision was generally better than 10%, varying somewhat with the analyte considered, With the proposed methodology, the amount of hazardous organic solvents used could be decreased and the sample throughput increased with at least a factor of two with less manual handling compared to the DIN method. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:215 / 227
页数:13
相关论文
共 15 条
[1]  
[Anonymous], 1997, 53316 DIN
[2]   NITROUS-OXIDE VERSUS CARBON-DIOXIDE FOR SUPERCRITICAL FLUID EXTRACTION AND CHROMATOGRAPHY OF AMINES [J].
ASHRAFKHORASSANI, M ;
TAYLOR, LT ;
ZIMMERMAN, P .
ANALYTICAL CHEMISTRY, 1990, 62 (11) :1177-1180
[3]   Mutagenicity and carcinogenicity of aromatic amines metabolically produced from azo dyes [J].
Chung, KT .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART C-ENVIRONMENTAL CARCINOGENESIS & ECOTOXICOLOGY REVIEWS, 2000, 18 (01) :51-74
[4]  
Cioni F, 1999, RAPID COMMUN MASS SP, V13, P1833, DOI 10.1002/(SICI)1097-0231(19990930)13:18<1833::AID-RCM725>3.0.CO
[5]  
2-R
[6]  
Ellis MK, 1997, J SOC LEATH TECH CH, V81, P52
[7]   Determination of some aromatic amines in finger-paints for children's use by supercritical fluid extraction combined with gas chromatography [J].
Garrigós, MC ;
Reche, F ;
Pernías, K ;
Sánchez, A ;
Jiménez, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :259-266
[8]   Optimization of parameters for the analysis of aromatic amines in finger-paints [J].
Garrigós, MC ;
Reche, F ;
Pernías, K ;
Jiménez, A .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :291-298
[9]   SUPERCRITICAL-FLUID EXTRACTION AND CHROMATOGRAPHY OF AROMATIC-AMINES [J].
JANDA, V ;
KRIZ, J ;
VEJROSTA, J ;
BARTLE, KD .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :241-245
[10]  
JAREMO M, 1998, THESIS LUND U LUND