Limb asymmetry in titanium Greenfield filters: Clinically significant?

被引:20
作者
Greenfield, LJ
Proctor, MC
Cho, KJ
Wakefield, TW
机构
[1] UNIV MICHIGAN HOSP,DEPT SURG,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN HOSP,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
D O I
10.1016/S0741-5214(97)70089-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The purpose of this study was to determine the outcomes for patients with titanium Greenfield vena caval filters (TGFs) and, in particular, to evaluate the effect of filter leg distribution on recurrent pulmonary embolism (PE) and caval occlusion. Methods: Physical examination, abdominal plain films, and duplex ultrasound examinations of the inferior vena cava and lower extremities were obtained annually and recorded in a Filter Database. Results: Seven hundred eighty-three TGFs have been placed since 1989. Follow-up was available for 373 patients, or 65% of the surviving patients, over 1 to 84 months (mean, 33 months). Asymmetry was identified in 42 placements (5%), and 35 of these patients had at least one follow-up examination. The overall incidence of recurrent PE was 3.2% (12 of 373), whereas the caval patency rate was 97.8% (265 of 271). These outcomes were not significantly different for patients who had asymmetric filters (p = 0.1 and 0.18, respectively). Conclusions: Filter leg distribution does not appear to be associated with an increased incidence of recurrent PE or caval occlusion. These data support earlier in vitro findings. The long-term results with the TGF are comparable with the results of the original stainless steel Greenfield filter.
引用
收藏
页码:770 / 775
页数:6
相关论文
共 11 条
[1]  
CHO KY, 1992, J VASC INTERV RADIOL, V3, P340
[2]  
Greenfield L J, 1995, Cardiovasc Surg, V3, P199, DOI 10.1016/0967-2109(95)90895-C
[3]  
GREENFIELD LJ, 1992, ARCH SURG-CHICAGO, V127, P969
[4]   EXPERIMENTAL EMBOLIC CAPTURE BY ASYMMETRIC GREENFIELD FILTERS [J].
GREENFIELD, LJ ;
PROCTOR, MC .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (03) :436-444
[5]   EXTENDED EVALUATION OF THE TITANIUM GREENFIELD VENA-CAVAL FILTER [J].
GREENFIELD, LJ ;
PROCTOR, MC ;
CHO, KJ ;
CUTLER, BS ;
FERRIS, EJ ;
MCFARLAND, D ;
SOBEL, M ;
TISNADO, J .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (03) :458-465
[6]  
GREENFIELD LJ, 1994, J VASC INTERV RADIOL, V5, P528, DOI 10.1016/S1051-0443(94)71547-5
[7]  
GREENFIELD LJ, 1991, J VASC SURG, V14, P253
[8]  
Millward S F, 1992, J Vasc Interv Radiol, V3, P103, DOI 10.1016/S1051-0443(92)72199-X
[9]  
Moore B S, 1993, J Vasc Interv Radiol, V4, P687, DOI 10.1016/S1051-0443(93)71949-1
[10]   COMPARATIVE-EVALUATION OF CLINICALLY AVAILABLE INFERIOR VENA-CAVA FILTERS WITH AN IN-VITRO PHYSIOLOGICAL SIMULATION OF THE VENA-CAVA [J].
SIMON, M ;
RABKIN, DJ ;
KLESHINSKI, S ;
KIM, D ;
RANSIL, BJ .
RADIOLOGY, 1993, 189 (03) :769-774