摘要
Background: Reproducibility concerns the degree to which repeated measurements provide similar results. Agreement parameters assess how close the results of the repeated measurements are, by estimating the measurement error in repeated measurements. Reliability parameters assess whether study objects, often persons, can be distinguished from each other, despite measurement errors. In that case, the measurement error is related to the variability between persons. Consequently, reliability parameters are highly dependent on the heterogeneity of the study sample, while the agreement parameters, based on measurement error, are more a pure characteristic of the measurement instrument. Methods and Results: Using an example of an interrater study, in which different physical therapists measure the range of motion of the arm in patients with shoulder complaints, the differences and relationships between reliability and agreement parameters for continuous variables are illustrated. Conclusion: If the research question concerns the distinction of persons, reliability parameters are the most appropriate. But if the aim is to measure change in health status, which is often the case in clinical practice, parameters of agreement are preferred. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1033 / 1039
页数:7
相关论文
共 14 条
[11]  
Shavelson R., 1991, GENERALIZABILITY THE
[12]   Use of the standard error as a reliability index of interest: An applied example using elbow flexor strength data [J].
Stratford, PW ;
Goldsmith, CH .
PHYSICAL THERAPY, 1997, 77 (07) :745-750
[13]  
Streiner DL, 2003, HLTH MEASUREMENT SCA
[14]  
Testa MA, 2000, MED CARE, V38, P166