Semi-automated liquid-liquid back-extraction in a 96-well format to decrease sample preparation time for the determination of dextromethorphan and dextrorphan in human plasma

被引:43
作者
Bolden, RD [1 ]
Hoke, SH [1 ]
Eichhold, TH [1 ]
McCauley-Myers, DL [1 ]
Wehmeyer, KR [1 ]
机构
[1] Procter & Gamble Pharmaceut, Mason, OH 45040 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 772卷 / 01期
关键词
sample preparation; dextromethorphan; dextrorphan;
D O I
10.1016/S0378-4347(01)00555-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A semi-automated, 96-well based liquid-liquid back-extraction (LLE) procedure was developed and used for sample preparation of dextromethorphan (DEX), an active ingredient in many over-the-counter cough formulations, and dextrorphan (DOR), an active metabolite of DEX, in human plasma. The plasma extracts were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS-MS). The analytes were isolated from human plasma using an initial ether extraction, followed by a back extraction from the ether into a small volume of acidified water. The acidified water isolated from the back extraction was analyzed directly by LC-MS-MS, eliminating the need for a dry down step. A liquid handling system was utilized for all aspects of liquid transfers during the LLE procedure including the transfer of samples from individual tubes into a 96-well format, preparation of standards, addition of internal standard and the addition and transfer of the extraction solvents. The semi-automated, 96-well based LLE procedure reduced sample preparation time by a factor of four versus a comparable manually performed LLE procedure. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 13 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]   Straightforward solid-phase extraction method for the determination of verapamil and its metabolite in plasma in a 96-well extraction plate [J].
Cheng, YF ;
Neue, UD ;
Bean, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :273-281
[4]   Rapid determination of the anti-cancer drug chlorambucil (Leukeran™) and its phenyl acetic acid mustard metabolite in human serum and plasma by automated solid-phase extraction and liquid chromatography-tandem mass spectrometry [J].
Davies, ID ;
Allanson, JP ;
Causon, RC .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01) :173-184
[5]  
Eichhold TH, 1997, J MASS SPECTROM, V32, P1205
[6]  
Janiszewski J, 1997, RAPID COMMUN MASS SP, V11, P1033
[7]  
Jemal M, 2000, RAPID COMMUN MASS SP, V14, P1023, DOI 10.1002/1097-0231(20000630)14:12<1023::AID-RCM983>3.0.CO
[8]  
2-K
[9]   Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry [J].
Jemal, M ;
Teitz, D ;
Ouyang, Z ;
Khan, S .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :501-508
[10]   Rapid, solid phase extraction technique for the high-throughput assay of darifenacin in human plasma [J].
Kaye, B ;
Herron, WJ ;
Macrae, PV ;
Robinson, S ;
Stopher, DA ;
Venn, RF ;
Wild, W .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1658-1660