A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N′-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine

被引:226
作者
Gupta, Vinod Kumar [1 ]
Singh, A. K. [1 ]
Gupta, Barkha [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
cerium selective electrode; polyvinyl chloride; membrane electrodes; Schiff base; potentiometric sensors;
D O I
10.1016/j.aca.2006.05.090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyvinyl chloride (PVC) based membrane sensor for cerium ions was prepared by employing N,N-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine as an ionophore, oleic acid (OA) as anion excluder and o-nitrophenyloctyl ether (o-NPOE) as plasticizer. The plasticized membrane sensor exhibits a Nernstian response for Ce(III) ions over a wide concentration range (1.41 X 10(-7) to 1.0 X 10(-2) M) with a limit of detection as low as 8.91 x 10(-8) M. It has a fast response time (< 10 s) and can be used for 4 months. The sensor revealed a very good selectivity with respect to common alkali, alkaline earth and heavy metal ions. The response of the proposed sensor is independent of pH between 3.0 and 8.0. It was used as an indicator electrode in potentiometric titration of fluoride, carbonate and oxalate anions and determination of cerium in simulated mixtures. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 54 条
[1]   Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base [J].
Abbaspour, A ;
Esmaeilbeig, AR ;
Jarrahpour, AA ;
Khajeh, B ;
Kia, R .
TALANTA, 2002, 58 (02) :397-403
[2]   DETERMINATION OF CERIUM, YTTRIUM AND THORIUM IN ENVIRONMENTAL-SAMPLES [J].
ACHILLI, M ;
CICERI, G ;
FERRAROLI, R ;
HELTAI, D ;
MARTINOTTI, W .
ANALYST, 1989, 114 (03) :319-323
[3]   A new cerium (III)-selective membrane electrode based on 2-aminobenzothiazole [J].
Akhond, M ;
Najafi, MB ;
Tashkhourian, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3) :410-415
[4]  
Amarchand S, 2000, ELECTROANAL, V12, P522, DOI 10.1002/(SICI)1521-4109(200005)12:7<522::AID-ELAN522>3.0.CO
[5]  
2-D
[6]   A rapid, selective and sensitive spectrophotometric method for the determination of Ce(III) using some bisazophenyl-beta-diketone derivatives [J].
Amin, AS ;
Moustafa, MM ;
Issa, RM .
TALANTA, 1997, 44 (03) :311-317
[7]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[8]   Cationic group 13 complexes [J].
Atwood, DA .
COORDINATION CHEMISTRY REVIEWS, 1998, 176 :407-430
[9]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[10]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132