Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories

被引:226
作者
Keyak, JH [1 ]
Rossi, SA [1 ]
机构
[1] Univ Calif Irvine, Irvine Med Ctr, Dept Orthopaed Surg, Orange, CA 92868 USA
关键词
hip fracture; osteoporosis; finite element; femur; bone strength;
D O I
10.1016/S0021-9290(99)00152-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Finite element (FE) models are often used to model bone failure. However. no failure theory for bone has been validated at this time. In this study, we examined the performance of nine stress- and strain-based failure theories, six of which could account for differences in tensile and compressive material strengths. The distortion energy, Hoffman and a strain-based Hoffman analog, maximum normal stress, maximum normal strain, maximum shear strain, maximum shear stress (tau(max)), Coulomb-Mohr, and modified Mohr failure theories were evaluated using automatically generated, computed tomographic scan-based FE models of the femur. Eighteen matched pairs of proximal femora were examined in two load configurations, one approximating joint loading during single-limb stance and one simulating impact from a fall. Mechanical testing was performed to assess model and failure theory performance in the context of predicting femoral fracture load. Measured and FE-computed fracture load were significantly correlated for both loading conditions and all failure criteria (p less than or equal to 0.001). The distortion energy and tau(max) failure theories were the most robust of those examined, providing the most consistently strong FE model performance for two very different loading conditions. The more complex failure theories and the strain-based theories examined did not improve performance over the simpler distortion energy and tau(max) theories, and often degraded performance, even when differences between tensile and compressive failure properties were represented. The relatively strong performance of the distortion energy and tau(max) theories supports the hypothesis that shear/distortion is an important failure mode during femoral fracture. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 17 条
[1]
FENECH CM, 1997, T ORS, V22, P38
[2]
The dependence of shear failure properties of trabecular bone on apparent density and trabecular orientation [J].
Ford, CM ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1309-1317
[3]
Ford CM, 1996, J BONE MINER RES, V11, P377
[4]
Hoffman O., 1967, J. Compos. Mater, V1, P200, DOI [DOI 10.1177/002199836700100210, 10.1177/002199836700100210]
[5]
DIFFERENCES BETWEEN THE TENSILE AND COMPRESSIVE STRENGTHS OF BOVINE TIBIAL TRABECULAR BONE DEPEND ON MODULUS [J].
KEAVENY, TM ;
WACHTEL, EF ;
FORD, CM ;
HAYES, WC .
JOURNAL OF BIOMECHANICS, 1994, 27 (09) :1137-1146
[6]
PREDICTING THE COMPRESSIVE MECHANICAL-BEHAVIOR OF BONE [J].
KELLER, TS .
JOURNAL OF BIOMECHANICS, 1994, 27 (09) :1159-1168
[7]
AUTOMATED 3-DIMENSIONAL FINITE-ELEMENT MODELING OF BONE - A NEW METHOD [J].
KEYAK, JH ;
MEAGHER, JM ;
SKINNER, HB ;
MOTE, CD .
JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (05) :389-397
[8]
CORRELATIONS BETWEEN ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF TRABECULAR BONE - USE OF DIFFERENT DENSITOMETRIC MEASURES [J].
KEYAK, JH ;
LEE, IY ;
SKINNER, HB .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (11) :1329-1336
[9]
Keyak JH, 1998, J BIOMECH, V31, P125, DOI 10.1016/S0021-9290(97)00123-1
[10]
ESTIMATION OF MATERIAL PROPERTIES IN THE EQUINE METACARPUS WITH USE OF QUANTITATIVE COMPUTED-TOMOGRAPHY [J].
LES, CM ;
KEYAK, JH ;
STOVER, SM ;
TAYLOR, KT ;
KANEPS, AJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) :822-833