Reliability and Repeatability of Cone Density Measurements in Patients with Congenital Achromatopsia

被引:41
作者
Abozaid, Mortada A. [1 ,2 ]
Langlo, Christopher S. [3 ]
Dubis, Adam M. [4 ,5 ]
Michaelides, Michel [4 ,5 ]
Tarima, Sergey [6 ]
Carroll, Joseph [1 ,3 ,7 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Dept Ophthalmol, 925 N 87th St, Milwaukee, WI 53226 USA
[2] Sohag Univ, Dept Ophthalmol, Sohag, Egypt
[3] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
[4] UCL, UCL Inst Ophthalmol, London, England
[5] Moorfields Eye Hosp, London, England
[6] Med Coll Wisconsin, Inst Hlth & Soc, Div Biostat, Milwaukee, WI 53226 USA
[7] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
来源
RETINAL DEGENERATIVE DISEASES: MECHANISMS AND EXPERIMENTAL THERAPY | 2016年 / 854卷
基金
英国惠康基金;
关键词
Achromatopsia; Adaptive optics; Repeatability; Reliability; Cone photoreceptor; ADAPTIVE OPTICS; OPHTHALMOSCOPE; RESOLUTION;
D O I
10.1007/978-3-319-17121-0_37
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
100103 [病原生物学]; 100218 [急诊医学];
摘要
Adaptive optics scanning light ophthalmoscopy (AOSLO) allows noninvasive assessment of the cone photoreceptor mosaic. Confocal AOSLO imaging of patients with achromatopsia (ACHM) reveals an altered reflectivity of the remaining cone structure, making identification of the cells more challenging than in normal retinas. Recently, a "split-detector" AOSLO imaging method was shown to enable direct visualization of cone inner segments in patients with ACHM. Several studies have demonstrated gene replacement therapy effective in restoring cone function in animal models of ACHM and human trials have on the horizon, making the ability to reliably assess cone structure increasingly important. Here we sought to examine whether absolute estimates of cone density obtained from split-detector and confocal AOSLO images differed from one another and whether the inter-and intra-observer reliability is significantly different between these modes. These findings provide an important foundation for evaluating the role of these images as tools to assess the efficacy of future gene therapy trials.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 13 条
[1]
Adaptive optics retinal imaging reveals S-cone dystrophy in tritan color-vision deficiency [J].
Baraas, Rigmor C. ;
Carroll, Joseph ;
Gunther, Karen L. ;
Chung, Mina ;
Williams, David R. ;
Foster, David H. ;
Neitz, Maureen .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1438-1447
[2]
Automatic cone photoreceptor segmentation using graph theory and dynamic programming [J].
Chiu, Stephanie J. ;
Lokhnygina, Yuliya ;
Dubis, Adam M. ;
Dubra, Alfredo ;
Carroll, Joseph ;
Izatt, Joseph A. ;
Farsiu, Sina .
BIOMEDICAL OPTICS EXPRESS, 2013, 4 (06) :924-937
[3]
Individual variations in human cone photoreceptor packing density: Variations with refractive error [J].
Chui, Toco Yuen Ping ;
Song, HongXin ;
Burns, Stephen A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4679-4687
[4]
Dubra A, 2010, 4 INT WORKSH BIOM IM
[5]
Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope [J].
Dubra, Alfredo ;
Sulai, Yusufu ;
Norris, Jennifer L. ;
Cooper, Robert F. ;
Dubis, Adam M. ;
Williams, David R. ;
Carroll, Joseph .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07) :1864-1876
[6]
High-resolution imaging with adaptive optics in patients with inherited retinal degeneration [J].
Duncan, Jacque L. ;
Zhang, Yuhua ;
Gandhi, Jarel ;
Nakanishi, Chiaki ;
Othman, Mohammad ;
Branham, Kari E. H. ;
Swaroop, Anand ;
Roorda, Austin .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3283-3291
[7]
Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements [J].
Garrioch, Robert ;
Langlo, Christopher ;
Dubis, Adam M. ;
Cooper, Robert F. ;
Dubra, Alfredo ;
Carroll, Joseph .
OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) :632-643
[8]
Photoreceptor Structure and Function in Patients with Congenital Achromatopsia [J].
Genead, Mohamed A. ;
Fishman, Gerald A. ;
Rha, Jungtae ;
Dubis, Adam M. ;
Bonci, Daniela Maria O. ;
Dubra, Alfredo ;
Stone, Edwin M. ;
Neitz, Maureen ;
Carroll, Joseph .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) :7298-7308
[9]
The reliability of parafoveal cone density measurements [J].
Liu, Benjamin S. ;
Tarima, Sergey ;
Visotcky, Alexis ;
Pechauer, Alex ;
Cooper, Robert F. ;
Landsem, Leah ;
Wilk, Melissa A. ;
Godara, Pooja ;
Makhijani, Vikram ;
Sulai, Yusufu N. ;
Syed, Najia ;
Yasumura, Galen ;
Garg, Anupam K. ;
Pennesi, Mark E. ;
Lujan, Brandon J. ;
Dubra, Alfredo ;
Duncan, Jacque L. ;
Carroll, Joseph .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (08) :1126-1131
[10]
Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope [J].
Merino, David ;
Duncan, Jacque L. ;
Tiruveedhula, Pavan ;
Roorda, Austin .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (08) :2189-2201