Development and application of a bioluminescence atp assay method for rapid detection of coliform bacteria

被引:25
作者
Tanaka, H
Shinji, T
Sawada, K
Monji, Y
Seto, S
Yajima, M
Yagi, O
机构
[1] NIHON NOSAN KOGYO KK,YOKOHAMA,KANAGAWA 22081,JAPAN
[2] NIHON MILLIPORE LTD,ANALYT DIV,SHINAGAWA KU,TOKYO 140,JAPAN
[3] ASAMA CHEM CO LTD,TOKYO,JAPAN
[4] NATL INST ENVIRONM STUDIES,WATER & SOIL ENVIRONM DIV,WATER QUAL SCI SECT,YATABE,IBARAKI 305,JAPAN
关键词
coliform; bioluminescence; ATP; luciferin; luciferase; rapid; detection; RMDS; membrane filter;
D O I
10.1016/S0043-1354(97)00032-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The conventional bacterial quantitative and qualitative methods are complex and require a lot of skills and time. Therefore a rapid microorganism detection system (RMDS) method was developed. With this method, yeast cells can be detected without cultivation, while some other microorganisms can be often detected after only 4-5 h of cultivation. The food sample is placed on a special membrane filter and cultivated on a plate until a sufficient amount of ATP is obtained. The membrane filter containing the microorganisms is then sprayed with the extractive and luminescent reagents and luciferin-luciferase reacts with the living cells. By this method, only the bioluminescent living cells are detected as spots. Thus, the RMDS method can detect the number but not the type of bacteria. An attempt to develop a method for the identification of coliforms, which is an index bacteria in food hygiene inspection, was made. In order to inhibit the growth of microorganisms which are closely related to the Pseudomonas genus and which form red colonies similar to coliforms as well as the germination of fungi spores, they were cultivated under anaerobic conditions in a new selective medium. Typical microorganisms which are often detected in foods, including yeasts, fungi, Gram-positive bacteria, Gram-negative bacteria (containing coliforms) and bacterial spores, were used. The sample was cultivated in an anaerobic L-shaped test-tube using the new coliform selective medium and then detected by the RMDS method. The results show that under this condition, the growth of both Pseudomonas sp. and fungi are suppressed, and coliforms could be detected within 6-7 h. This method is more rapid than the conventional method and has great potential for practical hygiene testing of both food beverages and water. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1913 / 1918
页数:6
相关论文
共 13 条
[1]   NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN WATER [J].
BRENNER, KP ;
RANKIN, CC ;
ROYBAL, YR ;
STELMA, GN ;
SCARPINO, PV ;
DUFOUR, AP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (11) :3534-3544
[2]  
DANKERT J, 1994, J CLIN MICROBIOL, V32, P2393
[3]   LUMINESCENCE-BASED DETECTION OF ACTIVITY OF STARVED AND VIABLE BUT NONCULTURABLE BACTERIA [J].
DUNCAN, S ;
GLOVER, LA ;
KILLHAM, K ;
PROSSER, JI .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1994, 60 (04) :1308-1316
[4]  
GONZALEZFLECHA B, 1994, J BACTERIOL, V176, P2293
[5]   ENZYME CAPTURE ASSAY FOR RAPID IDENTIFICATION OF ESCHERICHIA-COLI IN BLOOD CULTURES [J].
HUANG, SW ;
WU, JJ ;
CHANG, TC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (06) :1444-1448
[6]   A PHOTON-COUNTING TV CAMERA EQUIPPED WITH AN IMAGE GUIDE FOR RAPID DETECTION AND COUNTING OF SINGLE BACTERIA IN A WIDE FIELD [J].
MASUKO, M ;
KATAOKA, T ;
SUGIYAMA, N ;
UCHIYAMA, S ;
SUGIYAMA, H ;
TARUI, K ;
KAMIYA, K ;
KAWAI, T .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1992, 56 (01) :107-111
[7]   A NOVEL METHOD FOR DETECTION AND COUNTING OF SINGLE BACTERIA IN A WIDE FIELD USING AN ULTRA-HIGH-SENSITIVITY TV CAMERA WITHOUT A MICROSCOPE [J].
MASUKO, M ;
HOSOI, S ;
HAYAKAWA, T .
FEMS MICROBIOLOGY LETTERS, 1991, 81 (03) :287-290
[8]   DETECTION OF BACTERIAL ATP BY REVERSED FLOW-INJECTION ANALYSIS WITH LUMINESCENCE DETECTION [J].
MILLER, JN ;
NAWAWI, MB ;
BURGESS, C .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :339-343
[9]   APYRASE IMMOBILIZED ON PARAMAGNETIC BEADS USED TO IMPROVE DETECTION LIMITS IN BIOLUMINOMETRIC ATP MONITORING [J].
NYREN, P .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1994, 9 (01) :29-34
[10]   RAPID GLUTAMATE-DECARBOXYLASE ASSAY FOR DETECTION OF ESCHERICHIA-COLI [J].
RICE, EW ;
JOHNSON, CH ;
DUNNIGAN, ME ;
REASONER, DJ .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (12) :4347-4349