Meniscal repair with the RapidLoc meniscal repair device

被引:50
作者
Barber, F. Alan
Coons, David A.
Ruiz-Suarez, Michell
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX USA
[2] Pacific Sports Med, Tacoma, WA USA
[3] Natl Rehabil Hosp, Mexico City, DF, Mexico
关键词
meniscus; repair device; bioabsorbable; arthroscopy; RapidLoc; panacryl;
D O I
10.1016/j.arthro.2006.04.109
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The RapidLoc is an all-inside, self-adjusting, flexible meniscal repair device that combines a suture with an anchor component and, by using a reinforced sliding knot, allows for tightening to compress and hold the repaired meniscal segments. The purpose of this study was to evaluate the clinical success of the RapidLoc device. Methods: A prospective consecutive series of meniscal repairs performed with the RapidLoc device was studied. Lysholm, Tegner, Cincinnati, IKDC (International Knee Documentation Committee) activity scores, clinical examination findings, and adverse events were recorded on all patients. Associated procedures were recorded. An accelerated postoperative rehabilitation program was followed, independent of whether anterior cruciate ligament (ACL) surgery was also performed. Results: A total of 32 patients underwent 32 meniscal repairs, with an average follow-up of 31 months (18 to 48 months). In all, 23 repairs were done in conjunction with ACL reconstruction, and 9 repairs were carried out in stable knees. Repairs were made to 25 medial menisci and 7 lateral menisci. Tears repaired consisted of peripheral longitudinal tears with an average length of 2 cm (range, 15 to 30 mm). Four failures (12.5%) were arthroscopically documented. Clinical success occurred in 87.5% at the time of last follow-up. At follow-up, mean Tegner score was 5.1 (2.8 preoperative), IKDC activity score was 3.1 (1.8 preoperative), Lysholm score was 93.6 (48.4 preoperative), and mean Cincinnati score was 88.1 (43.7 preoperative). The most common adverse event was cutting of the suture during RapidLoc insertion. One patient had excoriation and grooving of the medial femoral condyle associated with failed repair. Another patient developed a postoperative infection. Conclusions: The early clinical success rate was 87.5% with the RapidLoc device. Chondral grooving was observed in a single case. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:962 / 966
页数:5
相关论文
共 21 条
[1]
Arthroscopic all-inside suture repair of medial meniscus lesion in anterior cruciate ligament-deficient knees: Results of second-look arthroscopies in 39 cases [J].
Ahn, JH ;
Wang, JH ;
Yoo, JC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (09) :936-945
[2]
Rapid progression of chondral disease in the lateral compartment of the knee following meniscectomy [J].
Alford, JW ;
Lewis, P ;
Kang, RW ;
Cole, BJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (12) :1505-1509
[3]
Barber F A, 2000, Am J Knee Surg, V13, P234
[4]
Barber F Alan, 2005, J Knee Surg, V18, P285
[5]
Arthroscopic meniscal repair using the BioStinger [J].
Barber, FA ;
Johnson, DH ;
Halbrecht, JL .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (06) :744-750
[6]
Chondral injury after arthroscopic meniscal repair using bioabsorbable Mitek RapidLoc meniscal fixation [J].
Cohen, SB ;
Anderson, MW ;
Miller, MD .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) :e73-e75
[7]
Marrow stimulating technique to augment meniscus repair [J].
Freedman, KB ;
Nho, SJ ;
Cole, BJ .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) :794-798
[8]
Meniscal repair using the FasT-Fix all-inside meniscal repair device [J].
Haas, AL ;
Schepsis, AA ;
Hornstein, J ;
Edgar, CM .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02) :167-175
[9]
Arthroscopic meniscal repair with an absorbable screw: results and surgical technique [J].
Hantes, ME ;
Kotsovolos, ES ;
Mastrokalos, DS ;
Ammenwerth, J ;
Paessler, HH .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (04) :273-279
[10]
Two-year follow-up of meniscal repair using a bioabsorbable arrow [J].
Jones, HP ;
Lemos, MJ ;
Wilk, RM ;
Smiley, PM ;
Gutierrez, R ;
Schepsis, AA .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01) :64-69