Results of contrast-medium supported 3D MR angiography in respiratory arrest after optimisation of contrast medium bolus.

被引:5
作者
Kopka, L [1 ]
Vosshenrich, R [1 ]
Muller, D [1 ]
Fischer, U [1 ]
Rodenwaldt, J [1 ]
Grabbe, E [1 ]
机构
[1] UNIV GOTTINGEN,RONGENDIAGNOST ABT 1,D-3400 GOTTINGEN,GERMANY
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 166卷 / 04期
关键词
MR; angiography; rapid imaging; contrast agents; gadolinium;
D O I
10.1055/s-2007-1015427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Reduction of the contrast material volume by optimised bolus administration during a breath-hold 3D MR angiography and its clinical value. Materials and methods: Breath-hold ultrafast 3D gadolinium-enhanced MR angiography (T-R 5 ms, T-E 2 ms, FA 20 degrees) of the thoracic and abdominal aorta was performed in 50 patients and correlated with an i.a. DSA. 25 patients (group I)were examined with a contrast material volume of 40 mi Cd-DTPA and three successive acquisitions at fixed intervals (25, 53 and 81 s) after start of the contrast material injection. Another group of 25 patients (group 2) received only 20 mi Gd-DTPA and the start of the MR acquisition was determined individually by prior evaluation of the contrast material transit times after injection of a test bolus. The signal-to-noise (S/N) and contrast-to-noise (GIN) ratios were compared and a subjective image quality rating (0-3) by three reviewers was achieved in both groups. Results: A total of 37 vascular pathologies were correctly detected by MR angiography compared to i.a. DSA. The grading of stenoses was overestimated in some cases. The S/N and C/N were higher in group 2 (63.2 and 50.1) than in group 1 (58.0 and 38.9). The subjective ratings also showed better results in group 2 (2.76) than in group 1 (2.20). Conclusion: The ultrafast gadolinium-enhanced 3D MR angiography allowed a reliable visualisation of the thoracic and abdominal aorta and its branches in a single breath-hold. An optimised examination with a reduced contrast material volume can be achieved by an individual adaptation of the MR acquisition to contrast material administration after measurement of the contrast material transit times.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 20 条
[1]   EVALUATION OF 2D- AND 3D-TIME-OF-FLIGHT-MRA IN RENAL-ARTERY STENOSIS [J].
ARLART, IP ;
GUHL, L ;
HAUSMANN, R .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (01) :59-64
[2]   A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES [J].
BOGDANOV, AA ;
WEISSLEDER, R ;
FRANK, HW ;
BOGDANOVA, AV ;
NOSSIF, N ;
SCHAFFER, BK ;
TSAI, E ;
PAPISOV, MI ;
BRADY, TJ .
RADIOLOGY, 1993, 187 (03) :701-706
[3]  
BORELLO JA, 1995, RADIOLOGY, V197, P793
[4]   IMAGING OF THE RENAL-ARTERIES - VALUE OF MR ANGIOGRAPHY [J].
DEBATIN, JF ;
SPRITZER, CE ;
GRIST, TM ;
BEAM, C ;
SVETKEY, LP ;
NEWMAN, GE ;
SOSTMAN, HD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) :981-990
[5]   MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PREOPERATIVE EVALUATION OF ABDOMINAL AORTIC-ANEURYSMS [J].
DURHAM, JR ;
HACKWORTH, CA ;
TOBER, JC ;
BOVA, JG ;
BENNETT, WF ;
SCHMALBROCK, P ;
VANAMAN, ME ;
HOROWITZ, JD ;
WRIGHT, JG ;
SMEAD, WL .
AMERICAN JOURNAL OF SURGERY, 1993, 166 (02) :173-178
[6]   DISSECTION OF THE THORACIC AORTA - PREOPERATIVE AND POSTOPERATIVE FINDINGS ON TURBO-FLASH MR-IMAGES OBTAINED IN THE PLANE OF THE AORTIC-ARCH [J].
FISCHER, U ;
VOSSHENRICH, R ;
KOPKA, L ;
KEATING, D ;
OESTMANN, JW ;
GRABBE, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1069-1072
[7]   MR-IMAGING OF THE THORACIC AORTA - COMPARISON OF SPIN-ECHO, ANGIOGRAPHIC, AND BREATH-HOLD TECHNIQUES [J].
HARTNELL, GG ;
FINN, JP ;
ZENNI, M ;
COHEN, MC ;
DUPUY, DE ;
WHEELER, HG ;
LONGMAID, HE .
RADIOLOGY, 1994, 191 (03) :697-704
[8]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[9]   ABDOMINAL-AORTA AND RENAL-ARTERY STENOSIS - EVALUATION WITH MR ANGIOGRAPHY [J].
KIM, D ;
EDELMAN, RR ;
KENT, KC ;
PORTER, DH ;
SKILLMAN, JJ .
RADIOLOGY, 1990, 174 (03) :727-731
[10]   PARENCHYMAL LIVER ENHANCEMENT WITH BOLUS-TRIGGERED HELICAL CT - PRELIMINARY CLINICAL-RESULTS [J].
KOPKA, L ;
FUNKE, M ;
FISCHER, U ;
VOSSHENRICH, R ;
OESTMANN, JW ;
GRABBE, E .
RADIOLOGY, 1995, 195 (01) :282-284