Binding assays in heterogeneous media using a flow injection system with an expanded micro-bed adsorption column

被引:7
作者
Mattiasson, B [1 ]
Nandakumar, MP [1 ]
机构
[1] Lund Univ, Ctr Chem & Chem Engn, Dept Biotechnol, S-22100 Lund, Sweden
关键词
expanded micro-bed; flow injection ELISA; immunoassay;
D O I
10.1023/A:1008092503961
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Competitive binding assays have been performed in flow injection systems. To further increase the versatility of the system, and to enable it to deal with samples containing particulate matter, the adsorption step was designed as an expanded bed column. Immunochemical quantification of human serum albumin was chosen as a model system to use for the development of the technology. A competitive ELISA was set up using peroxidase labelled HSA as competing ligand. The introduction of the expanded bed immunosorption column made the system tolerant to samples containing suspended particulate matter. The analytical outcome is very similar to that from the packed bed system even though more time is required for each assay cycle. The capability of the system was tested by addition of increasing amounts of yeast cells. The results clearly indicate that the system is suitable e.g. for process monitoring of fermentations.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 24 条
[1]   THERMOMETRIC ENZYME LINKED IMMUNOSORBENT ASSAY IN CONTINUOUS-FLOW SYSTEM - OPTIMIZATION AND EVALUATION USING HUMAN-SERUM ALBUMIN AS A MODEL SYSTEM [J].
BORREBAECK, C ;
BORJESON, J ;
MATTIASSON, B .
CLINICA CHIMICA ACTA, 1978, 86 (03) :267-278
[2]   DEVELOPMENT OF AN EXPANDED BED TECHNIQUE FOR AN AFFINITY PURIFICATION OF G6PDH FROM UNCLARIFIED YEAST-CELL HOMOGENATES [J].
CHANG, YK ;
MCCREATH, GE ;
CHASE, HA .
BIOTECHNOLOGY AND BIOENGINEERING, 1995, 48 (04) :355-366
[3]   A CRITICAL-EVALUATION OF THE MECHANISM OF POTENTIAL RESPONSE OF ANTIGEN POLYMER MEMBRANES TO THE CORRESPONDING ANTISERUM [J].
COLLINS, S ;
JANATA, J .
ANALYTICA CHIMICA ACTA, 1982, 136 (APR) :93-99
[4]   SURFACE-PLASMON RESONANCE APPLIED TO IMMUNOSENSING [J].
DANIELS, PB ;
DEACON, JK ;
EDDOWES, MJ ;
PEDLEY, DG .
SENSORS AND ACTUATORS, 1988, 15 (01) :11-18
[5]   GENERAL SAMPLING SYSTEM FOR STERILE MONITORING OF BIOLOGICAL PROCESSES [J].
HAKANSON, H ;
NILSSON, M ;
MATTIASSON, B .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :61-65
[6]   A CONTINUOUS-FLOW IMMUNOASSAY FOR RAPID AND SENSITIVE DETECTION OF SMALL MOLECULES [J].
KUSTERBECK, AW ;
WEMHOFF, GA ;
CHARLES, PT ;
YEAGER, DA ;
BREDEHORST, R ;
VOGEL, CW ;
LIGLER, FS .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) :191-197
[7]  
Lali A., 1997, ISOL PURIF, V2, P289
[8]   AUTOMATION OF AN ENERGY-TRANSFER IMMUNOASSAY BY USING STOPPED-FLOW INJECTION-ANALYSIS WITH MERGING ZONES [J].
LIM, CS ;
MILLER, JN ;
BRIDGES, JW .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :183-189
[9]  
Maggio E.T., 1980, ENZYME IMMUNOASSAY
[10]   PROCESS-CONTROL OF AN ETHANOL FERMENTATION WITH AN ENZYME THERMISTOR AS A SUCROSE SENSOR [J].
MANDENIUS, CF ;
DANIELSSON, B ;
MATTIASSON, B .
BIOTECHNOLOGY LETTERS, 1981, 3 (11) :629-634