Finite element analysis of human knee joint in varus-valgus

被引:191
作者
Bendjaballah, MZ
ShiraziAdl, A
Zukor, DJ
机构
[1] ECOLE POLYTECH, DEPT MECH ENGN, DIV APPL MECH, MONTREAL, PQ H3C 3A7, CANADA
[2] MCGILL UNIV, JEWISH GEN HOSP, DEPT ORTHOPAED SURG, MONTREAL, PQ H3T 1E2, CANADA
关键词
biomechanics; finite element analysis; knee joint; ligaments; varus-valgus; articulation; menisci; cartilage;
D O I
10.1016/S0268-0033(97)00072-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The overall response, load transmission, role of ligaments, and state of stress in various components under varus-valgus moments in the intact and collateral-deficient tibiofemoral joint are investigated. Design. A non-linear finite element model consisting of bony structures (tibia and femur), their articular cartilage layers, medial and lateral menisci and four primary ligaments (cruciates and collaterals) is utilized. Background. Valgus and varus stresses are among the primary mechanisms of injury to knee ligaments. Several in vitro studies have investigated the role of ligaments in resisting such loads and on the way deficiency in either collateral may affect the response. Methods. Cartilage layers are isotropic while menisci are non-homogeneous composite. The articulation of cartilage layers with each other and with the intervening menisci and the wrapping of the medial collateral ligament around the tibial edge are treated as large displacement frictionless contact problems. The non-linear elastostatic response of the joint at full extension is computed under varus-valgus moments applied to the femur with the tibia fixed. Cases simulating deficiency in collaterals and constraint on femoral axial rotation are also studied. Results. The response is non-linear with large coupled axial rotations, internal in varus and external in valgus. In intact and collateral-deficient states, the joint shows varus or valgus openings so that the articulation occurs at one plateau only, medial in varus and lateral in valgus. Large tensile forces in cruciates in collateral-cut models generate higher compression penalty on the loaded plateau. Conclusions. Collaterals are the primary load-bearing structures; their absence would substantially increase primary laxities, coupled axial rotations, forces in cruciates, and articular contact forces. Good agreement with measurements is found. Relevance Detailed knowledge of joint biomechanics is essential in the diagnosis, prevention and treatment of observed disorders. Absence of collateral ligaments increases the loads in cruciates and contact stresses transmitted through cartilage layers and menisci, and thus places the affected components at more risk, especially when varus-valgus is accompanied by other modes of loading as well. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 48 条
[31]   THE CONTRIBUTION OF THE CRUCIATE LIGAMENTS TO THE LOAD-DISPLACEMENT CHARACTERISTICS OF THE HUMAN KNEE-JOINT [J].
PIZIALI, RL ;
RASTEGAR, J ;
NAGEL, DA ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (04) :277-283
[32]   MEASUREMENT OF NONLINEAR, COUPLED STIFFNESS CHARACTERISTICS OF HUMAN KNEE [J].
PIZIALI, RL ;
RASTEGAR, JC ;
NAGEL, DA .
JOURNAL OF BIOMECHANICS, 1977, 10 (01) :45-51
[33]   THE MECHANICAL-PROPERTIES OF THE 2 BUNDLES OF THE HUMAN POSTERIOR CRUCIATE LIGAMENT [J].
RACE, A ;
AMIS, AA .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :13-24
[34]   EFFECT OF FIXED AXES OF ROTATION ON THE VARUS-VALGUS AND TORSIONAL LOAD-DISPLACEMENT CHARACTERISTICS OF THE INVITRO HUMAN KNEE [J].
RASTEGAR, J ;
PIZIALI, RL ;
NAGEL, DA ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1979, 101 (02) :134-140
[35]  
Sauren A.A.H.J., 1984, INT J SPORTS MED, V5, P93
[36]   THE FUNCTION OF THE PRIMARY LIGAMENTS OF THE KNEE IN VARUS-VALGUS AND AXIAL ROTATION [J].
SEERING, WP ;
PIZIALI, RL ;
NAGEL, DA ;
SCHURMAN, DJ .
JOURNAL OF BIOMECHANICS, 1980, 13 (09) :785-794
[37]   PREDICTION OF MUSCULAR LOAD SHARING AND JOINT FORCES IN LOWER-EXTREMITIES DURING WALKING [J].
SEIREG, A ;
ARVIKAR, RJ .
JOURNAL OF BIOMECHANICS, 1975, 8 (02) :89-102
[38]  
SHAPIRO MS, 1991, J BONE OINT SURG A, V72, P557
[39]   A FINITE-ELEMENT STUDY OF A LUMBAR MOTION SEGMENT SUBJECTED TO PURE SAGITTAL PLANE MOMENTS [J].
SHIRAZIADL, A ;
AHMED, AM ;
SHRIVASTAVA, SC .
JOURNAL OF BIOMECHANICS, 1986, 19 (04) :331-350
[40]   STRAIN IN FIBERS OF A LUMBAR-DISK - ANALYSIS OF THE ROLE OF LIFTING IN PRODUCING DISK PROLAPSE [J].
SHIRAZIADL, A .
SPINE, 1989, 14 (01) :96-103