Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes

被引:1013
作者
Musameh, M
Wang, J [1 ]
Merkoci, A
Lin, YH
机构
[1] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国国家卫生研究院;
关键词
NADH; carbon nanotubes; fouling; electrocatalysis; biosensors;
D O I
10.1016/S1388-2481(02)00451-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Carbon-nanotube (CNT)-modified glassy carbon electrodes exhibiting strong and stable electrocatalytic response toward NADH are described. A substantial (490 mV) decrease in the overvoltage of the NADH oxidation reaction (compared to ordinary carbon electrodes) is observed using single-wall and multi-wall carbon-nanotube coatings, with oxidation starting at ca. -0.05 V (vs. Ag/AgCl; pH 7.4). Furthermore, the NADH amperometric response of the coated electrodes is extremely stable, with 96% and 90% of the initial activity remaining after 60 min stirring of 2 x 10(-4) and 5 x 10(-3) M NADH solutions, respectively (compared to 20% and 14% at the bare surface). The CNT-coated electrodes thus allow highly sensitive, low-potential, stable amperometric sensing. Such ability of carbon nanotubes to promote the NADH electron-transfer reaction suggests great promise for dehydrogenase-based amperometric biosensors. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:743 / 746
页数:4
相关论文
共 13 条
  • [1] Electrocatalytic detection of NADH and glycerol by NAD+-modified carbon electrodes
    Alvarez-González, MI
    Saidman, SA
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (03) : 520 - 527
  • [2] STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE
    BLAEDEL, WJ
    JENKINS, RA
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (08) : 1337 - 1343
  • [3] Gorton Lo, 2002, J Biotechnol, V82, P371, DOI 10.1016/S1389-0352(01)00053-8
  • [4] CATALYTIC-OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE BY GRAPHITE-ELECTRODES MODIFIED WITH ADSORBED AROMATICS CONTAINING CATECHOL FUNCTIONALITIES
    JAEGFELDT, H
    TORSTENSSON, ABC
    GORTON, LGO
    JOHANSSON, G
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (13) : 1979 - 1982
  • [5] Amperometric biosensors based on NAD(P)-dependent dehydrogenase enzymes
    Lobo, MJ
    Miranda, AJ
    Tunon, P
    [J]. ELECTROANALYSIS, 1997, 9 (03) : 191 - 202
  • [6] Rao CNR, 2001, CHEMPHYSCHEM, V2, P78, DOI 10.1002/1439-7641(20010216)2:2<78::AID-CPHC78>3.0.CO
  • [7] 2-7
  • [8] AMPEROMETRIC BIOSENSING OF ALCOHOLS AT ELECTROCHEMICALLY PRETREATED GLASSY-CARBON ENZYME ELECTRODES
    WANG, J
    GONZALEZROMERO, E
    [J]. ELECTROANALYSIS, 1993, 5 (5-6) : 427 - 430
  • [9] SCANNING TUNNELING MICROSCOPIC PROBING OF SURFACE FOULING DURING THE OXIDATION OF NICOTINAMIDE COENZYMES
    WANG, J
    ANGNES, L
    MARTINEZ, T
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 29 (02): : 215 - 221
  • [10] Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes
    Wang, JX
    Li, MX
    Shi, ZJ
    Li, NQ
    Gu, ZN
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (09) : 1993 - 1997