A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources

被引:121
作者
Ding, L [1 ]
Sudakov, M [1 ]
Brancia, FL [1 ]
Giles, R [1 ]
Kumashiro, S [1 ]
机构
[1] Shimadzu Res Lab Europe Ltd, Manchester M17 1GP, Lancs, England
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 05期
关键词
quadrupole ion trap; digital ion trap; resonance ejection; resolution; precursor isolation; tandem mass spectrometry; atmospheric pressure ionization;
D O I
10.1002/jms.637
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:471 / 484
页数:14
相关论文
共 43 条
[11]  
2-M
[12]  
Floquet G., 1883, ANN SCI ECOLE NORM S, V12, P47, DOI [DOI 10.24033/ASENS.220, 10.24033/asens.220, 10.24033/asens.220/]
[13]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[14]  
Kelley PE, 1992, US Patent, Patent No. 5134286
[15]   Matrix methods for the calculation of stability diagrams in quadrupole mass spectrometry [J].
Konenkov, NV ;
Sudakov, M ;
Douglas, DJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (06) :597-613
[16]   Electron capture dissociation of multiply charged peptide cations [J].
Kruger, NA ;
Zubarev, RA ;
Horn, DM ;
McLafferty, FW .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 185 :787-793
[17]   Stability of ion motion in the quadrupole ion trap driven by rectangular waveform voltages [J].
Lee, WW ;
Min, SK ;
Oh, CH ;
Kim, PS ;
Song, SH ;
Yang, M ;
Song, KS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 230 (01) :65-70
[18]   Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap [J].
Li, HY ;
Plass, WR ;
Patterson, GE ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (10) :1051-1058
[19]   INSTRUMENTATION, APPLICATIONS, AND ENERGY DEPOSITION IN QUADRUPOLE ION-TRAP TANDEM MASS-SPECTROMETRY [J].
LOURIS, JN ;
COOKS, RG ;
SYKA, JEP ;
KELLEY, PE ;
STAFFORD, GC ;
TODD, JFJ .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1677-1685
[20]  
March RE, 1997, J MASS SPECTROM, V32, P351, DOI 10.1002/(SICI)1096-9888(199704)32:4<351::AID-JMS512>3.3.CO