Attomole protein characterization by capillary electrophoresis mass spectrometry

被引:334
作者
Valaskovic, GA [1 ]
Kelleher, NL [1 ]
McLafferty, FW [1 ]
机构
[1] CORNELL UNIV,BAKER LAB,DEPT CHEM,ITHACA,NY 14853
关键词
D O I
10.1126/science.273.5279.1199
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Electrospray ionization with an ultralow flow rate (less than or equal to 4 nanoliters per minute) was used to directly couple capillary electrophoresis with tandem mass spectrometry for the analysis and identification of biomolecules in mixtures. A Fourier transform mass spectrometer provided full spectra (>30 kilodaltons) at a resolving power of approximate to 60,000 for injections of 0.7 x 10(-18) to 3 x 10(-18) mole of 8- to 29-kilodalton proteins with errors of <1 dalton in molecular mass. Using a crude isolate from human blood, a value of 28,780.6 daltons (calculated, 28,780.4 daltons) was measured for carbonic anhydrase, representing 1 percent by weight of the protein in a single red blood cell. Dissociation of molecular ions from 9 x 10(-18) mole of carbonic anhydrase gave nine sequence-specific fragment ions, more data than required for unique retrieval of this enzyme from the protein database.
引用
收藏
页码:1199 / 1202
页数:4
相关论文
共 37 条
[1]   FOURIER-TRANSFORM ELECTROSPRAY INSTRUMENTATION FOR TANDEM HIGH-RESOLUTION MASS-SPECTROMETRY OF LARGE MOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
WAMPLER, FM ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :557-565
[2]   PROBING C-60 [J].
CURL, RF ;
SMALLEY, RE .
SCIENCE, 1988, 242 (4881) :1017-1022
[3]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[4]   ANALYTICAL-CHEMISTRY IN MICROENVIRONMENTS - SINGLE NERVE-CELLS [J].
EWING, AG ;
STREIN, TG ;
LAU, YY .
ACCOUNTS OF CHEMICAL RESEARCH, 1992, 25 (10) :440-447
[5]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[6]   IDENTIFICATION OF RECEPTOR LIGANDS AND RECEPTOR SUBTYPES USING ANTAGONISTS IN A CAPILLARY ELECTROPHORESIS SINGLE-CELL BIOSENSOR SEPARATION SYSTEM [J].
FISHMAN, HA ;
ORWAR, O ;
SCHELLER, RH ;
ZARE, RN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (17) :7877-7881
[7]  
Flaming K.T., 1986, ADV MICROPIPETTE TEC
[8]  
FOSKETT JK, 1990, NONINVASIVE TECHNIQU, V9
[9]  
Herman B., 1990, OPTICAL MICROSCOPY B
[10]  
Hofstadler SA, 1996, RAPID COMMUN MASS SP, V10, P919, DOI 10.1002/(SICI)1097-0231(19960610)10:8<919::AID-RCM597>3.0.CO