Factors affecting the accuracy of multicomponent kinetic-spectrophotometric determinations based on multivariate calibration methods

被引:5
作者
Cullen, TF [1 ]
Crouch, SR [1 ]
机构
[1] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
关键词
multicomponent kinetic-spectrophotometric determination; multivariate technique;
D O I
10.1016/S0003-2670(99)00836-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of experimental variables on the accuracy of multicomponent kinetic-spectrophotometric determinations using multivariate calibration techniques is reported. Kinetic and spectral angles are introduced and shown to be good descriptors of the quantity of analytical information present in kinetic-spectrophotometric data. The components of these descriptor angles are described. The effects of instrumental noise and rate constant fluctuation are contrasted. An equilibrium spectrophotometric determination of gallium(III) and nickel(II) is compared to a kinetic determination and a kinetic-spectrophotometric determination. The effect of changing experimental variables (e.g., pH and wavelength range) is discussed, and conclusions are drawn. (C)2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 146
页数:12
相关论文
共 44 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   KINETIC DETERMINATION OF COBALT AND NICKEL BY FLOW-INJECTION SPECTROPHOTOMETRY [J].
ARRUDA, MAZ ;
ZAGATTO, EAG ;
MANIASSO, N .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :476-480
[3]   AUTOMATED STOPPED-FLOW SPECTROPHOTOMETER WITH DIGITAL SEQUENCING FOR MILLISECOND ANALYSES [J].
BECKWITH, PM ;
CROUCH, SR .
ANALYTICAL CHEMISTRY, 1972, 44 (02) :221-&
[4]  
BEEBE KR, 1998, CHEMOMETRIC TECHNIQU
[5]   KINETIC SPECTROPHOTOMETRIC METHOD FOR ANALYZING MIXTURES OF METAL-IONS BY STOPPED-FLOW INJECTION-ANALYSIS USING PARTIAL LEAST-SQUARES REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2905-2911
[6]  
Blanco M, 1996, QUIM ANAL, V15, P266
[7]   KINETIC SPECTROPHOTOMETRIC DETERMINATION OF GA(III)-AL(III) MIXTURES BY STOPPED-FLOW INJECTION-ANALYSIS USING PRINCIPAL COMPONENT REGRESSION [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J ;
ROVIRA, E .
TALANTA, 1993, 40 (02) :261-267
[8]   ARTIFICIAL NEURAL NETWORKS FOR MULTICOMPONENT KINETIC DETERMINATIONS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4477-4483
[9]   PARTIAL LEAST-SQUARES REGRESSION FOR MULTICOMPONENT KINETIC DETERMINATIONS IN LINEAR AND NONLINEAR-SYSTEMS [J].
BLANCO, M ;
COELLO, J ;
ITURRIAGA, H ;
MASPOCH, S ;
REDON, M .
ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) :309-320
[10]   Artificial neural networks and partial least squares regression for pseudo-first-order with respect to the reagent multicomponent kinetic-spectrophotometric determinations [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Redon, M ;
Villegas, N .
ANALYST, 1996, 121 (04) :395-400