Relationship between size of injected microspheres and ultrasound imaging of heart by PLSR

被引:8
作者
Dyrstad, K [1 ]
Sontum, PC [1 ]
机构
[1] NYCOMED AS,RES & DEV SECT,ANALYT SCI,N-0401 OSLO,NORWAY
关键词
ultrasound imaging; heart; microspheres; multivariate analysis;
D O I
10.1023/A:1012197427698
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. To investigate the enhancement in ultrasound signal (US) in heart, for diagnostic purposes, as a function of size and number of injected air-filled microspheres by multivariate statistical methods. Methods. The US enhancement in left ventricle was measured after injection of 31 suspensions of air-filled albumin microspheres divided on and injected in six dogs. The relationship between the size of microspheres between 1-38 mu m and the US enhancement was explored by Pearson's product moment correlation analysis, ordinary least-squares regression, principal component regression (PCR) and partial least-squares regression (PLS). Results. Relative advanced algorithms such as PCR and PLS were required to achieve accurate in vivo/in vitro correlation. The most effective microsphere sizes contributing to US enhancement in left ventricle in dogs were estimated to be in the 7-15 mu m range. Conclusions. In general, the effective in vivo sizes are dependent on the type of formulation due to the surprisingly large active in vivo sizes found for the tested concept. PCR and PLS are suitable methods for in vivo/in vitro correlation, especially for covariated and noisy data.
引用
收藏
页码:1485 / 1489
页数:5
相关论文
共 11 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
Bhattacharyya G. K., 1977, STAT CONCEPTS METHOD
[3]  
CHRISTIANSEN C, 1994, BIOTECHNOL APPL BIOC, V19, P307
[4]   ULTRASOUND SCATTERING PROPERTIES OF ALBUNEX MICROSPHERES [J].
DEJONG, N ;
HOFF, L .
ULTRASONICS, 1993, 31 (03) :175-181
[5]   ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS [J].
DEJONG, N ;
HOFF, L ;
SKOTLAND, T ;
BOM, N .
ULTRASONICS, 1992, 30 (02) :95-103
[6]   A STATISTICAL VIEW OF SOME CHEMOMETRICS REGRESSION TOOLS [J].
FRANK, IE ;
FRIEDMAN, JH .
TECHNOMETRICS, 1993, 35 (02) :109-135
[7]  
HOFF L, 1994, J ULTRAS MED, V13, P181
[8]  
Kvale S, 1997, COMPUT CHEM ENG, V21, pS343
[9]  
SCLIEF R, 1988, JB RADIOLOGIE, P163
[10]   PRECISION AND ACCURACY OF ANALYSIS OF AIR-FILLED ALBUMIN MICROSPHERES USING COULTER-MULTISIZER-MARK-II [J].
SONTUM, PC ;
CHRISTIANSEN, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (10) :1233-1241