Perfusion CT in patients with advanced bronchial carcinomas:: a novel chance for characterization and treatment monitoring?

被引:95
作者
Kiessling, F [1 ]
Boese, J [1 ]
Corvinus, C [1 ]
Ederle, JR [1 ]
Zuna, I [1 ]
Schoenberg, SO [1 ]
Brix, G [1 ]
Schmähl, A [1 ]
Tuengerthal, S [1 ]
Herth, F [1 ]
Kauczor, HU [1 ]
Essig, M [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Oncol Diagnost & Therapy, D-69120 Heidelberg, Germany
关键词
perfusion; lung neoplasms; tomography; X-ray computed;
D O I
10.1007/s00330-004-2288-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (I scan/s) at a fixed table position. Density-time curves were evaluated from regions of interest of the whole tumor and high- and low-enhancing tumor areas. Perfusion and peak enhancement were calculated using the maximum-slope method of Miles and compared with size, localization (central or peripheral) and histology. Perfusion of large tumors (>50 cm(3)) averaged over both the whole tumor (P=0.001) and the highest enhancing area (P=0.003) was significantly lower than that of smaller ones. Independent of size, central carcinomas had a significantly (P=0.04) lower perfusion (mean 27.9 ml/min/100 g) than peripheral ones (mean 66.5 ml/min/100 9). In contrast, peak enhancement of central and peripheral carcinomas was not significantly different. Between non-small-cell lung cancers and small-cell lung cancers, no significant differences were observed in both parameters. In seven tumors, density increase after CM administration started earlier than in the aorta, indicating considerable blood supply from pulmonary vessels. Tumor perfusion was dependent on tumor size and localization, but not on histology. Furthermore, perfusion CT disclosed blood supply from both pulmonary and/or bronchial vessels in some tumors.
引用
收藏
页码:1226 / 1233
页数:8
相关论文
共 27 条
  • [1] [Anonymous], 1990, ICRP PUBL
  • [2] Barentsz JO, 1999, J MAGN RESON IMAGING, V10, P295, DOI 10.1002/(SICI)1522-2586(199909)10:3<295::AID-JMRI10>3.0.CO
  • [3] 2-Z
  • [4] Hemodynamic effects of decompressive craniotomy in MCA infarction:: evaluation with perfusion CT
    Bendszus, M
    Müllges, W
    Goldbrunner, R
    Weigand, A
    Solymosi, L
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (08) : 1895 - 1898
  • [5] A survey of PET activity in Germany during 1999
    Brix, G
    Nosske, D
    Glatting, G
    Minkov, V
    Reske, SN
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (08) : 1091 - 1097
  • [6] Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience
    Brix, G
    Bahner, ML
    Hoffmann, UJ
    Horvath, A
    Schreiber, W
    [J]. RADIOLOGY, 1999, 210 (01) : 269 - 276
  • [7] Coleman RE, 1999, J NUCL MED, V40, P814
  • [8] Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent
    Davis, PL
    McCarty, KS
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (Suppl 5) : S289 - S298
  • [9] Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    Diederich, S
    Wormanns, D
    Semik, M
    Thomas, M
    Lenzen, H
    Roos, N
    Heindel, W
    [J]. RADIOLOGY, 2002, 222 (03) : 773 - 781
  • [10] Griffon-Etienne G, 1999, CANCER RES, V59, P3776