Determination of trace amounts of boron in rainwater by ICP-IDMS and NTI-IDMS and the dependence on meteorological and anthropogenic influences

被引:18
作者
Demuth, N [1 ]
Heumann, KG [1 ]
机构
[1] Univ Mainz, Inst Inorgan Chem & Analyt Chem, D-55099 Mainz, Germany
关键词
D O I
10.1039/a901515i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different mass spectrometric methods, inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and negative thermal ionisation isotope dilution mass spectrometry (NTI-IDMS), were applied to the determination of trace concentrations of boron in rainwater samples. After carrying out the isotope dilution step, ICP-MS was directly used for the measurement of the B-11/B-10 ratio. For NTI-IDMS, the isotope diluted boron was first separated by a boron selective ion exchanger and then the boron isotope ratio was determined by measuring negative BO2- thermal ions. Boron concentrations of 21 rainwater samples from different parts of Germany and from the Jungfraujoch in Switzerland at an altitude of about 3600 m were determined to be in the range 0.3-7 ng ml(-1). The detection limits were 0.2 and 0.3 ng ml(-1) for ICP-IDMS and NTI-IDMS using 3 and 50 ml sample volumes, respectively. NTI-IDMS determinations were about a factor of 2.5 more time-consuming compared with ICP-IDMS. However, the boron concentrations determined by ICP-IDMS often showed slightly higher values than those determined by NTI-IDMS, which was due to contributions of relatively high C-12(+) ion intensities to the B-11(+) intensity when using a quadrupole ICP-MS instrument with insufficient mass resolution. ICP-IDMS is a fast and reliable method for the determination of boron concentrations down to < 1 ng ml(-1) in aquatic systems if mass resolution between mass numbers 11 and 12 is under control, whereas NTI-IDMS can be best applied as an accurate reference method at these low concentration levels. Significant dependence of the boron concentration in rainwater on the meteorological conditions, but not on the season of sampling, as well as anthropogenic influences, especially on the altitude of the sample collection place, was found by applying both mass spectrometric methods.
引用
收藏
页码:1449 / 1453
页数:5
相关论文
共 16 条
[1]   BORON ISOTOPE ANALYSIS - A REVIEW [J].
AGGARWAL, JK ;
PALMER, MR .
ANALYST, 1995, 120 (05) :1301-1307
[2]  
[Anonymous], 1988, INORGANIC MASS SPECT
[3]   Comparison of NTIMS and ICP-OES methods for the determination of boron concentrations in natural fresh and saline waters [J].
Barth, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (7-8) :854-855
[4]   Isotope dilution analysis for flow injection ICPMS determination of microgram per gram levels of boron in iron and steel after matrix removal [J].
Coedo, AG ;
Dorado, T ;
Fernandez, BJ ;
Alguacil, FJ .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :991-996
[5]  
DELAETER JR, 1991, PURE APPL CHEM, V63, P991
[6]   SENSITIVE DETERMINATION OF TRACES OF BORON IN WATERS, FERTILIZERS AND GEOLOGICAL AND BIOLOGICAL-MATERIALS BY ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
DUCHATEAU, NL ;
VERBRUGGEN, A ;
HENDRICKX, F ;
DEBIEVRE, P .
ANALYTICA CHIMICA ACTA, 1987, 196 :41-47
[7]  
Eisenhut S, 1996, FRESEN J ANAL CHEM, V354, P903
[9]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[10]   BORON TRACE DETERMINATION IN METALS AND ALLOYS BY ISOTOPE-DILUTION MASS-SPECTROMETRY WITH NEGATIVE THERMAL IONIZATION [J].
HEUMANN, KG ;
ZEININGER, H .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 67 (02) :237-252