Accuracy of computer-assisted pedicle screw placement - An in vivo computed tomography analysis

被引:195
作者
Schwarzenbach, O
Berlemann, U
Jost, B
Visarius, H
Arm, E
Langlotz, F
Nolte, LP
Ozdoba, C
机构
[1] UNIV BERN,ME MULLER INST BIOMECH,CH-3010 BERN,SWITZERLAND
[2] UNIV BERN,INSELSPITAL,DEPT ORTHOPAED SURG,CH-3010 BERN,SWITZERLAND
[3] UNIV BERN,INSELSPITAL,DEPT NEURORADIOL,CH-3010 BERN,SWITZERLAND
关键词
D O I
10.1097/00007632-199702150-00020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A computer-assisted planning and visualization system (the Orthopaedic Surgery Planning System) was tested for pedicle screw insertion in vivo. Objectives. To evaluate the system's applicability for regular intraoperative use and its accuracy for pedicle screw placement in vivo. Summary of Background Data. Pedicle screw placement poses considerable anatomic and biomechanical risks. The reported rates of screw misplacement with conventional insertion techniques are unacceptably high. It previously has been shown in vitro that computer assistance offers the potential to decrease the number of screws perforating the pedicular cortex. Methods. The accuracy of 162 pedicle screws inserted with the Orthopaedic Surgery Planning System was assessed by means oi postoperative computed tomography evaluation. Reconstructions of the horizontal, frontal, and sagittal planes were analyzed. Cortex perforations were graded in steps of 2 mm. Results. The cortex was perforated in 2.7% of pedicles. Complete preoperative computed tomography scanning of the levels to be operated on is essential to allow for a precise image reconstruction. Initial difficulties in applying he system contribute to the malplacements. A learning curve for general handling of the Orthopaedic Surgery Planning System was observed. Conclusions. The system provides a safe and reproducible technique for pedicle screw insertion. Other applications in the field of spine surgery are under evaluation.
引用
收藏
页码:452 / 458
页数:7
相关论文
共 42 条
[1]   PEDICLE DIAMETER DETERMINED BY COMPUTED-TOMOGRAPHY - ITS RELEVANCE TO PEDICLE SCREW FIXATION IN THE LUMBAR SPINE [J].
BERNARD, TN ;
SEIBERT, CE .
SPINE, 1992, 17 (06) :S160-S163
[2]   A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[3]   INTRAOPERATIVE EVOKED EMG MONITORING IN AN ANIMAL-MODEL - A NEW TECHNIQUE FOR EVALUATING PEDICLE SCREW PLACEMENT [J].
CALANCIE, B ;
LEBWOHL, N ;
MADSEN, P ;
KLOSE, KJ .
SPINE, 1992, 17 (10) :1229-1235
[4]  
CARL AL, 1995, P 10 ANN M N AM SPIN, P102
[5]   COMPLICATIONS OF LUMBAR SPINAL-FUSION WITH TRANSPEDICULAR INSTRUMENTATION [J].
DAVNE, SH ;
MYERS, DL .
SPINE, 1992, 17 (06) :S184-S189
[6]   THE FIXATUER-INTERNE AS A VERSATILE IMPLANT FOR SPINE SURGERY [J].
DICK, W .
SPINE, 1987, 12 (09) :882-900
[7]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[8]   ACCURACY OF PEDICLE SCREW PLACEMENT IN LUMBAR FUSIONS BY PLAIN RADIOGRAPHS AND COMPUTED-TOMOGRAPHY [J].
FARBER, GL ;
PLACE, HM ;
MAZUR, RA ;
JONES, DEC ;
DAMIANO, TR .
SPINE, 1995, 20 (13) :1494-1499
[9]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[10]  
Guven O, 1994, Orthop Rev, V23, P511