Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model

被引:216
作者
Landman, J [1 ]
Kerbl, K
Rehman, J
Andreoni, C
Humphrey, PA
Collyer, W
Olweny, E
Sundaram, C
Clayman, RV
机构
[1] Washington Univ, Sch Med, Dept Surg, Div Urol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Pathol, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Dept Immunol, St Louis, MO 63110 USA
[4] Univ Fed Sao Paulo, Div Urol, Sao Paulo, Brazil
[5] Univ Calif Irvine, Dept Urol, Orange, CA 92668 USA
关键词
laparoscopy; swine; blood vessels; surgical equipment; hemostasis;
D O I
10.1016/S0022-5347(05)63995-X
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities. Materials and Methods: A total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated. Results: The 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm. Conclusions: In the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.
引用
收藏
页码:697 / 700
页数:4
相关论文
共 3 条
  • [1] CHANDLER JG, 1997, ANN C EUR ASS END SU
  • [2] High-burst-strength, feedback-controlled bipolar vessel sealing
    Kennedy, JS
    Stranahan, PL
    Taylor, KD
    Chandler, JG
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1998, 12 (06): : 876 - 878
  • [3] Kerbl K, 1993, J Laparoendosc Surg, V3, P9, DOI 10.1089/lps.1993.3.9