A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium

被引:89
作者
Guntupalli, R.
Hu, J.
Lakshmanan, Ramji S.
Huang, T. S.
Barbaree, James M.
Chin, Bryan A. [1 ]
机构
[1] Auburn Univ, Mat Res & Educ Ctr, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Nutr & Food Sci, Auburn, AL 36849 USA
[3] Auburn Univ, Dept Biol Sci, Auburn, AL 36849 USA
[4] Jiangsu Polytech Univ, Dept Mat Sci & Engn, Changzhou 213016, Peoples R China
关键词
magnetoelastic; magnerostrictive; biosensor; antibody; Salmonella typhimurium; Langmuir Blodgett;
D O I
10.1016/j.bios.2006.06.037
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Mass-sensitive, magnetoelastic resonance sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted by the sensor in response to an applied, time varying, magnetic field. This magnetostrictive platform has a unique advantage over conventional sensor platforms in that measurement is wireless and remote. A biosensor for the detection of Salmonella typhimurium was constructed by immobilizing a polyclonal antibody (the bio-molecular recognition element) onto the surface of a magnetostrictive platform. The biosensor was then exposed to solutions containing S. typhimurium bacteria. Binding between the antibody and antigen (bacteria) occurred and the additional mass of the bound bacteria caused a shift in the sensor's resonant frequency. Sensors with different physical dimensions were exposed to different concentrations of S. typhimurium ranging from 10(2) to 10(9) CFU/ml. Detection limits of 5 x 10(3) CFU/ml, 10(5) CFU/ml and 10(7) CFU/ml were obtained for sensors with the size of 2 mm x 0.4 mm x 15 mu m, 5 mm. x 1 mm x 15 mu m and 25 mm x 5 mm x 15 mu m, respectively. Good agreement between the measured number of bound bacterial cells (as measured by scanning electron microscopy (SEM)) and frequency shifts was obtained. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1474 / 1479
页数:6
相关论文
共 23 条
[1]  
BAILEY CA, 2003, THESIS AUBURN U AUBU, P105
[2]   Blood rheological characterization using the thickness-shear mode resonator [J].
Bandey, HL ;
Cernosek, RW ;
Lee, WE ;
Ondrovic, LE .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (12) :1657-1665
[3]  
BECKERS HJ, 1998, FOOD MICROBIOL, V5, P147
[4]   A wireless, remote query ammonia sensor [J].
Cai, QY ;
Jain, MK ;
Grimes, CA .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (03) :614-619
[5]   Simultaneous measurement of liquid density and viscosity using remote query magnetoelastic sensors [J].
Grimes, CA ;
Kouzoudis, D ;
Mungle, C .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (10) :3822-3824
[6]   COMPARISON OF COLD ENRICHMENT AND UNITED-STATES-DEPARTMENT-OF-AGRICULTURE METHODS FOR ISOLATING LISTERIA-MONOCYTOGENES FROM NATURALLY CONTAMINATED FOODS [J].
HAYES, PS ;
GRAVES, LM ;
AJELLO, GW ;
SWAMINATHAN, B ;
WEAVER, RE ;
WENGER, JD ;
SCHUCHAT, A ;
BROOME, CV .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (08) :2109-2113
[7]   A comparison of protocols for the optimisation of detection of bacteria using a surface acoustic wave (SAW) biosensor [J].
Howe, E ;
Harding, G .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :641-649
[8]   Magnetoacoustic remote query temperature and humidity sensors [J].
Jain, MK ;
Schmidt, S ;
Ong, KG ;
Mungle, C ;
Grimes, CA .
SMART MATERIALS & STRUCTURES, 2000, 9 (04) :502-510
[9]   Application of a chromogenic medium and the PCR method for the rapid confirmation of L. monocytogenes in foodstuffs [J].
Karpísková, R ;
Pejchalová, M ;
Mokrosová, J ;
Vytrasová, J ;
Smuharová, P ;
Ruprich, J .
JOURNAL OF MICROBIOLOGICAL METHODS, 2000, 41 (03) :267-271
[10]   A novel FRET-based optical fiber biosensor for rapid detection of Salmonella typhimurium [J].
Ko, SH ;
Grant, SA .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :1283-1290