Blood rheological characterization using the thickness-shear mode resonator

被引:30
作者
Bandey, HL
Cernosek, RW [1 ]
Lee, WE
Ondrovic, LE
机构
[1] Sandia Natl Labs, Microsensor Res & Dev Dept, Albuquerque, NM 87185 USA
[2] Univ S Florida, Tampa, FL 33620 USA
基金
美国能源部;
关键词
blood; rheological characterization; thickness-shear mode resonator;
D O I
10.1016/j.bios.2004.01.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thickness-shear mode (TSM) resonators have been used to characterize static rheological properties of plasma and whole blood samples. We demonstrated simple and rapid techniques for determining plasma viscosity without cell separation, for measuring erythrocyte sedimentation rate, and for tracking blood coagulation throughout the entire process. Additionally, mathematical models, previously developed to characterize surface-loaded resonators, were used to extract non-Newtonian and viscoelastic material properties of blood layers during sedimentation and coagulation experiments. These studies indicate the utility of the TSM resonator for several clinical applications. Because the resonators can be miniaturized, potential exists for extending the techniques for use inside the body or blood stream (in vivo). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1657 / 1665
页数:9
相关论文
共 22 条
[1]  
Ballantine D.S., 1997, ACOUSTIC WAVE SENSOR
[2]   Modeling the responses of thickness-shear mode resonators under various loading conditions [J].
Bandey, HL ;
Martin, SJ ;
Cernosek, RW ;
Hillman, AR .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2205-2214
[3]   ERYTHROCYTE SEDIMENTATION-RATE - FROM FOLKLORE TO FACTS [J].
BEDELL, SE ;
BUSH, BT .
AMERICAN JOURNAL OF MEDICINE, 1985, 78 (06) :1001-1009
[4]  
Burton AC., 1972, PHYSL BIOPHYSICS CIR, V2
[5]   A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood [J].
Cheng, TJ ;
Chang, HC ;
Lin, TM .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :147-156
[6]  
GROSS DR, 1981, RHEOLOGY BLOOD BLOOD
[7]   FREQUENCY OF A QUARTZ MICROBALANCE IN CONTACT WITH LIQUID [J].
KANAZAWA, KK ;
GORDON, JG .
ANALYTICAL CHEMISTRY, 1985, 57 (08) :1770-1771
[8]  
Lowe G DO., 1988, Clinical Blood Rheology, V1, P11
[9]  
MARTIN SJ, 1993, PROCEEDINGS OF THE 1993 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, P603, DOI 10.1109/FREQ.1993.367450
[10]   SENSING LIQUID PROPERTIES WITH THICKNESS-SHEAR MODE RESONATORS [J].
MARTIN, SJ ;
FRYE, GC ;
WESSENDORF, KO .
SENSORS AND ACTUATORS A-PHYSICAL, 1994, 44 (03) :209-218