摘要
The study was performed to compare the effect of magnesium modifier (magnesium nitrate) with that of other modifiers (palladium nitrate and nickel nitrate) in determination of arsenic, antimony and selenium by atomic absorption spectroscopy with atomization in a graphite tube, with generation of hydrides and in situ preconcentration in a graphite tube. The assumed criterion of a modifier performance was the magnitude of the analytical signal. It was found that in determinations with atomization in a graphite furnace the effects of all these modifiers were comparable, while in those with hydride generation and in situ preconcentration in a graphite tube the magnesium modifier showed poorer performance (25% decrease of the analytical signal). In determinations of arsenic and selenium the analytical signal obtained with magnesium salt as a modifier was comparable with those obtained in the presence of all other modifiers. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:137 / 145
页数:9
相关论文
共 25 条
[1]   DETERMINATION OF TRACE AMOUNTS OF SELENIUM AND TELLURIUM IN HIGH-PURITY IRON BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER REDUCTIVE COPRECIPITATION WITH PALLADIUM USING ASCORBIC-ACID [J].
ASHINO, T ;
TAKADA, K ;
HIROKAWA, K .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :443-451
[2]   Selective medium reactions for the 'arsenic(III)', 'arsenic(V)', dimethylarsonic acid and monomethylarsonic acid determination in waters by hydride generation on-line electrothermal atomic absorption spectrometry with in situ preconcentration on Zr-coated graphite tubes [J].
Bermejo-Barrera, P ;
Moreda-Piñeiro, J ;
Moreda-Piñeiro, A ;
Bermejo-Barrera, A .
ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) :231-240
[3]   Comparison of chemical modifiers for the determination of selenium by electrothermal atomic-absorption spectrometry [J].
Bulska, E ;
Pyrzynska, K .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) :1283-1291
[4]   Determination of arsenic species in seawater by flow injection hydride generation in situ collection followed by graphite furnace atomic absorption spectrometry - Stability of As(III) [J].
Cabon, JY ;
Cabon, N .
ANALYTICA CHIMICA ACTA, 2000, 418 (01) :19-31
[5]   DETERMINATION OF SB, NI AND V IN SLURRY FROM AIRBORNE PARTICULATE MATERIAL COLLECTED ON FILTER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CARNEIRO, MC ;
CAMPOS, RC ;
CURTIUS, AJ .
TALANTA, 1993, 40 (12) :1815-1822
[6]   THE DETERMINATION OF ARSENIC BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH A GRAPHITE-FURNACE .2. DETERMINATION OF ARSENIC(III) AND ARSENIC(V) AFTER EXTRACTION [J].
CHAKRABORTI, D ;
DEJONGHE, W ;
ADAMS, F .
ANALYTICA CHIMICA ACTA, 1980, 120 (NOV) :121-127
[7]  
Chwastowska J, 1996, CHEM ANAL-WARSAW, V41, P45
[8]  
De-qiang Z., 1997, FRESEN J ANAL CHEM, V359, P492
[9]  
DEDINA J, 1995, HYDRIDE GENERATION A
[10]   Electrolytic hydride generation electrothermal atomic absorption spectrometry - in situ trapping of As on different pre-conditioned end-heated graphite tubes [J].
Denkhaus, E ;
Golloch, A ;
Kampen, TU ;
Nierfeld, M ;
Telgheder, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (6-7) :733-737