Evaluation of MISPE for the multi-residue extraction of β-agonists from calves urine

被引:59
作者
Widstrand, C [1 ]
Larsson, F
Fiori, M
Civitareale, C
Mirante, S
Brambilla, G
机构
[1] MIP Technol AB, SE-22370 Lund, Sweden
[2] Ist Super Sanita, I-00161 Rome, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 804卷 / 01期
关键词
molecular imprinting; beta-agonists;
D O I
10.1016/j.jchromb.2003.12.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methods based on molecular recognition mechanisms for the clean-up of veterinary drugs and their residues, such as immuno-, receptor- and acceptor-affinity and molecularly imprinted polymers (MIPs), have been described as selective tools to improve the selectivity and the reliability of analytical results. In this work, we tested the extraction recovery performances of a MISPE column, designed for multi-residual clean-up of beta-agonists. For this purpose, 18 different samples of calf urine were spiked at 0.25, 0.50 and 1.00 ppb with pooled standard solutions of clenbuterol (Clen), tulobuterol (Tolu), isoxsuprine (Isox), brombuterol (Brom), mapenterol (Mape) and ractopamine (Racto) and analysed on two independent analytical sessions, on a LC-MS/MS ion trap detector. Averaged recoveries, constant for each molecule considered, were 64.6% for Racto, 63.0% for Salm, 59.9% for Form, 54.7% for Brom, 52.0% for Clen, 41.8% for Mape, 38.6% for Tolu and 34.5% for Isox, respectively. Reproducibility studies gave a CV < 11% at the 0.25 ppb level. The decision limit for the identification of the target drugs ranged from 0.01 ppb for mapenterol to 0.19 ppb for salmeterol, when considering one precursor, and two product ions as identification points. Such findings indicate that the choice of the appropriate molecule as template in the MIP preparation is the critical factor to guarantee a reliable analytical multi-residue approach for beta-agonists, despite the structural differences among molecules exploiting almost the same pharmacological effect. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 22 条
[1]   A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting [J].
Andersson, LI ;
Paprica, A ;
Arvidsson, T .
CHROMATOGRAPHIA, 1997, 46 (1-2) :57-62
[2]   Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography with UV detection [J].
Blomgren, A ;
Berggren, C ;
Holmberg, A ;
Larsson, F ;
Sellergren, B ;
Ensing, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :157-164
[3]  
Bocca B, 2003, J AOAC INT, V86, P8
[4]   Use of molecularly imprinted polymers in the solid-phase extraction of clenbuterol from animal feeds and biological matrices [J].
Brambilla, G ;
Fiori, M ;
Rizzo, B ;
Crescenzi, V ;
Masci, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 759 (01) :27-32
[5]   Determination of new β2-agonist drugs by α1-acid glycoprotein affinity chromatography [J].
Gallo, P ;
Brambilla, G ;
Fiori, M ;
Scaramuzzo, A ;
Serpe, L .
CHROMATOGRAPHIA, 2001, 53 (Suppl 1) :S446-S449
[6]  
GARCIALOPEZ A, 2002, REV SANID MILIT MEX, V56
[7]   Immuno-based sample preparation for trace analysis [J].
Hennion, MC ;
Pichon, V .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :29-52
[8]   COMPETITIVE AMPEROMETRIC MORPHINE SENSOR-BASED ON AN AGAROSE IMMOBILIZED MOLECULARLY IMPRINTED POLYMER [J].
KRIZ, D ;
MOSBACH, K .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :71-75
[9]   Stanol/sterol ester-containing foods and blood cholesterol levels - A Statement for Healthcare Professionals from the Nutrition Committee of the Council on Nutrition, Physical Activity, and Metabolism of the American Heart Association [J].
Lichtenstein, AH ;
Deckelbaum, RJ .
CIRCULATION, 2001, 103 (08) :1177-1179
[10]   Evaluation of a molecular-imprinted polymer for use in the solid phase extraction of propranolol from biological fluids [J].
Martin, P ;
Wilson, ID ;
Morgan, DE ;
Jones, GR ;
Jones, K .
ANALYTICAL COMMUNICATIONS, 1997, 34 (02) :45-47