Improved B0-Distortion Correction in Diffusion MRI Using Interlaced q-Space Sampling and Constrained Reconstruction

被引:17
作者
Bhushan, Chitresh [1 ]
Joshi, Anand A. [1 ]
Leahy, Richard M. [1 ]
Haldar, Justin P. [1 ]
机构
[1] Univ So Calif, Inst Signal & Image Proc, Ming Hsieh Dept Elect Engn, Los Angeles, CA 90089 USA
关键词
diffusion magnetic resonance imaging; distortion correction; echo-planar imaging; B-0-field inhomogeneity; interlaced q-space sampling; constrained reconstruction; ITERATIVE IMAGE-RECONSTRUCTION; ECHO-PLANAR IMAGES; INDUCED DISTORTION; FIELDS; EPI;
D O I
10.1002/mrm.25026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo enable high-quality correction of susceptibility-induced geometric distortion artifacts in diffusion magnetic resonance imaging (MRI) images without increasing scan time. Theory and MethodsA new method for distortion correction is proposed based on subsampling a generalized version of the state-of-the-art reversed-gradient distortion correction method. Rather than acquire each q-space sample multiple times with different distortions (as in the conventional reversed-gradient method), we sample each q-space point once with an interlaced sampling scheme that measures different distortions at different q-space locations. Distortion correction is achieved using a novel constrained reconstruction formulation that leverages the smoothness of diffusion data in q-space. ResultsThe effectiveness of the proposed method is demonstrated with simulated and in vivo diffusion MRI data. The proposed method is substantially faster than the reversed-gradient method, and can also provide smaller intensity errors in the corrected images and smaller errors in derived quantitative diffusion parameters. ConclusionThe proposed method enables state-of-the-art distortion correction performance without increasing data acquisition time. Magn Reson Med 72:1218-1232, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1218 / 1232
页数:15
相关论文
共 33 条
[1]   Measurement of fiber orientation distributions using high angular resolution diffusion imaging [J].
Anderson, AW .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1194-1206
[2]  
Andersson J., 2010, Diffusion MRI: Theory, Methods, and Applications, P285, DOI DOI 10.1093/MED/9780195369779.003.0017
[3]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[4]   Log-euclidean metrics for fast and simple calculus on diffusion tensors [J].
Arsigny, Vincent ;
Fillard, Pierre ;
Pennec, Xavier ;
Ayache, Nicholas .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :411-421
[5]  
Caruyer Emmanuel, 2013, Magn Reson Med, V69, P1534, DOI 10.1002/mrm.24736
[6]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[7]   Regularized, fast, and robust analytical Q-Ball imaging [J].
Descoteaux, Maxime ;
Angelino, Elaine ;
Fitzgibbons, Shaun ;
Deriche, Rachid .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) :497-510
[8]   Peripheral nerve stimulation in a whole-body echo-planar imaging system [J].
Ehrhardt, JC ;
Lin, CS ;
Magnotta, VA ;
Fisher, DJ ;
Yuh, WTC .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :405-409
[9]   Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity [J].
Fessler, JA ;
Lee, S ;
Olafsson, VT ;
Shi, HR ;
Noll, DC .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2005, 53 (09) :3393-3402
[10]   More IMPATIENT: A gridding-accelerated Toeplitz-based strategy for non-Cartesian high-resolution 3D MRI on GPUs [J].
Gai, Jiading ;
Obeid, Nady ;
Holtrop, Joseph L. ;
Wu, Xiao-Long ;
Lam, Fan ;
Fu, Maojing ;
Haldar, Justin P. ;
Hwu, Wen-mei W. ;
Liang, Zhi-Pei ;
Sutton, Bradley P. .
JOURNAL OF PARALLEL AND DISTRIBUTED COMPUTING, 2013, 73 (05) :686-697