Peripheral nerve stimulation in a whole-body echo-planar imaging system

被引:26
作者
Ehrhardt, JC
Lin, CS
Magnotta, VA
Fisher, DJ
Yuh, WTC
机构
[1] Department of Radiology, University of Iowa, Iowa City, IA
[2] Georgetown University Medical Center, Washington, DC
[3] Department of Radiology, University of Washington, Seattle, WA
[4] Department of Radiology, University of Iowa, Iowa City
关键词
echo-planar imaging; peripheral nerve stimulation;
D O I
10.1002/jmri.1880070226
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Echo-planar techniques in MRI use a rapidly oscillating frequency-encoding gradient with the potential to produce peripheral nerve stimulation, To evaluate the incidence, type, and location of stimulation in a commercial whole-body scanner, we studied two groups: (a) 173 consecutive individuals scanned by echo-planar imaging for other purposes and (b) seven subjects who were scanned with an extensive set of 36 echo-planar sequences (with prompting after each scan to report any peripheral nerve stimulation) to test the effects of various parameters. Although only 5% of group A reported symptoms of peripheral nerve stimulation, all in group B experienced some type of stimulation, dependent primarily on direction of the oscillating gradient and location of the body within the gradient coil. Maximum stimulation typically occurred 30 to 40 cm from isocenter in the region of maximum dB/dt. Generally, y gradients produced truncal stimulation, and x gradients produced stimulation in the head. When hands were clasped over the abdomen, a tingling in the hands occasionally was felt, Patients should be instructed to keep their hands apart.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 20 条
[1]  
BARKER AT, 1985, LANCET, V1, P1106
[2]  
BOURLAND JD, 1990, P SOC MAGN RES MED A, P1157
[3]   PHYSIOLOGICAL-EFFECTS OF FAST OSCILLATING MAGNETIC-FIELD GRADIENTS [J].
BUDINGER, TF ;
FISCHER, H ;
HENTSCHEL, D ;
REINFELDER, HE ;
SCHMITT, F .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (06) :909-914
[4]  
CARBUNARU R, 1996, P 4 ANN M INT SOC MA, P1768
[5]   SENSORY STIMULATION BY TIME-VARYING MAGNETIC-FIELDS [J].
COHEN, MS ;
WEISSKOFF, RM ;
RZEDZIAN, RR ;
KANTOR, HL .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :409-414
[6]  
EBERHARDT KEW, 1995, P 3 ANN M SOC MAGN R, P1221
[7]  
ERHARD P, 1995, P 3 ANN M SOC MAGN R, P1219
[8]   AVOIDING PERIPHERAL-NERVE STIMULATION - GRADIENT WAVE-FORM CRITERIA FOR OPTIMUM RESOLUTION IN ECHO-PLANAR IMAGING [J].
HARVEY, PR ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) :236-241
[9]   MAGNETOSTIMULATION IN MRI [J].
IRNICH, W ;
SCHMITT, F .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :619-623
[10]   LIMITS TO NEURAL STIMULATION IN ECHO-PLANAR IMAGING [J].
MANSFIELD, P ;
HARVEY, PR .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :746-758