Measurement of intraventricular pressure and cardiac performance in the intact closed-chest anesthetized mouse

被引:98
作者
Lorenz, JN [1 ]
Robbins, J [1 ]
机构
[1] CHILDRENS HOSP RES FDN, DEPT PEDIAT, CINCINNATI, OH 45267 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1997年 / 272卷 / 03期
关键词
first derivative of ventricular pressure wave; heart; hypothyroid; hyperthyroid; myocardial function;
D O I
10.1152/ajpheart.1997.272.3.H1137
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To fully utilize the potential of newly developed mouse models with specific genetic mutations, it is necessary to study the functional consequences of genetic manipulation in the fully intact animal. To this end, the purpose of the present study was to develop and validate a methodology for the study of myocardial performance in the fully intact, closed-chest mouse. Left ventricular function was evaluated in euthyroid, hypothyroid, and hyperthyroid mice, animals with well-documented alterations in myocardial function. The mice were anesthetized and instrumented with polyethylene catheters in the right femoral artery and vein and with a Millar MIKRO-TIP transducer in the left, ventricle via the right carotid artery. Structural and functional evidence suggested that the instrumentation procedure did not cause myocardial damage, valvular insufficiency, or aortic obstruction. Isovolumic indexes of myocardial contractility derived from the left ventricular pressure pulse and its first derivative demonstrated a 40% increase in contractility in the hyperthyroid animals and a 40% decrease in contractility in the hypothyroid animals. Similar differences in the indexes of relaxation were observed. Furthermore, isoproterenol dose-response relationships of these contractile parameters were blunted in the hypothyroid animals and augmented in the hyperthyroid animals compared with euthyroid control animals. Given the small size of the mouse and the high frequency of the cardiac cycle, these data demonstrate the feasibilty of combining a high-fidelity, microtip manometer with a high-speed data-acquisition system to obtain faithful recordings of cardiac performance in the fully intact mouse.
引用
收藏
页码:H1137 / H1146
页数:10
相关论文
共 32 条
  • [21] BIOCHEMICAL AND PHYSIOLOGIC EFFECTS OF THYROID-HORMONE ON CARDIAC-PERFORMANCE
    MORKIN, E
    FLINK, IL
    GOLDMAN, S
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1983, 25 (05) : 435 - 464
  • [22] REGULATION OF MYOCARDIAL CA-2+-ATPASE AND PHOSPHOLAMBAN MESSENGER-RNA EXPRESSION IN RESPONSE TO PRESSURE OVERLOAD AND THYROID-HORMONE
    NAGAI, R
    ZARAINHERZBERG, A
    BRANDL, CJ
    FUJII, J
    TADA, M
    MACLENNAN, DH
    ALPERT, NR
    PERIASAMY, M
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (08) : 2966 - 2970
  • [23] ASSESSMENT OF MYOCARDIAL CONTRACTILITY FROM VENTRICULAR PRESSURE RECORDINGS
    NEJAD, NS
    KLEIN, MD
    MIRSKY, I
    LOWN, B
    [J]. CARDIOVASCULAR RESEARCH, 1971, 5 (01) : 15 - &
  • [24] CARDIAC MYOSIN HEAVY-CHAIN MESSENGER-RNA EXPRESSION AND MYOCARDIAL-FUNCTION IN THE MOUSE HEART
    NG, WA
    GRUPP, IL
    SUBRAMANIAM, A
    ROBBINS, J
    [J]. CIRCULATION RESEARCH, 1991, 68 (06) : 1742 - 1750
  • [25] ASSESSMENT OF DIASTOLIC FUNCTION OF THE HEART - BACKGROUND AND CURRENT APPLICATIONS OF DOPPLER ECHOCARDIOGRAPHY .1. PHYSIOLOGIC AND PATHOPHYSIOLOGIC FEATURES
    NISHIMURA, RA
    HOUSMANS, PR
    HATLE, LK
    TAJIK, AJ
    [J]. MAYO CLINIC PROCEEDINGS, 1989, 64 (01) : 71 - 81
  • [26] FUNCTIONAL EVIDENCE FOR DIFFERENTIAL REGULATION OF BETA-ADRENOCEPTOR SUBTYPES
    ODONNELL, SR
    WANSTALL, JC
    [J]. TRENDS IN PHARMACOLOGICAL SCIENCES, 1987, 8 (07) : 265 - 268
  • [27] ORLOWSKI J, 1990, J BIOL CHEM, V265, P3462
  • [28] THE THYROID AND THE HEART
    POLIKAR, R
    BURGER, AG
    SCHERRER, U
    NICOD, P
    [J]. CIRCULATION, 1993, 87 (05) : 1435 - 1441
  • [29] ROHRER D, 1988, J BIOL CHEM, V263, P6941
  • [30] Taffet GE, 1996, AM J PHYSIOL-HEART C, V270, pH2204