Motion sensor accuracy under controlled and free-living conditions

被引:179
作者
Le Masurier, GC [1 ]
Lee, SM [1 ]
Tudor-Locke, C [1 ]
机构
[1] Arizona State Univ E, Dept Exercise & Wellness, Mesa, AZ 85212 USA
关键词
pedometers; accelerometers; error; steps;
D O I
10.1249/01.MSS.0000126777.50188.73
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Two studies were conducted to examine the concurrent accuracy of the Yamax SW-200 (YAM), Omron HJ-105 (OM), and Sportline 330 (SL) pedometers, as well as a CSA accelerometer. Methods: In study 1, motion sensor performance was evaluated against actual (observed) steps taken during 5-min bouts at five different treadmill speeds (54, 67, 80, 94, and 107 m-min(-1)) using a two-way repeated measures ANOVA (instrument X speed). Additionally, the direction and magnitude of motion sensor error was examined. In study 2, pedometer performance during 24 h of free-living was evaluated against the steps detected by the CSA criterion. The direction and magnitude of pedometer error was also examined in the free-living condition. Results: In study 1, the SL showed significant differences from actual steps taken at all treadmill speeds (P < 0.05). Further, the absolute value of percent error was greatest for the SL at all treadmill speeds. At the slowest treadmill speed (54 m-min(-1)), the absolute value of percent error increased for the YAM and OM. In study 2, only the SL detected fewer steps than the CSA criterion (P < 0.05). The YAM demonstrated the lowest absolute value of percent error under free-living conditions. Conclusions: Different brands of motion sensors detect steps differently; therefore, caution must be used when comparing step counts between studies that have employed different brands of motion sensors. Taking into consideration the results of both studies and the initial walking test used for instrument screening purposes, it appears that, of the three pedometers tested, the YAM pedometer is most consistently accurate under both controlled and free-living conditions. Future research must consider presenting motion sensor accuracy in absolute terms so that the magnitude of error is not underestimated.
引用
收藏
页码:905 / 910
页数:6
相关论文
共 13 条
  • [1] [Anonymous], 2003, Meas. Phys. Educ. Exerc. Sci
  • [2] Accuracy of five electronic pedometers for measuring distance walked
    Bassett, DR
    Ainsworth, BE
    Leggett, SR
    Mathien, CA
    Main, JA
    Hunter, DC
    Duncan, GE
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) : 1071 - 1077
  • [3] Reexamination of validity and reliability of the CSA monitor in walking and running
    Brage, S
    Wedderkopp, N
    Franks, PW
    Andersen, LB
    Froberg, K
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) : 1447 - 1454
  • [4] Crouter S. E., 2003, Medicine & Science in Sports & Exercise, V35, pS283, DOI 10.1097/00005768-200305001-01571
  • [5] Validity of accelerometry for the assessment of moderate intensity physical activity in the field
    Hendelman, D
    Miller, K
    Bagget, C
    Debold, E
    Freedson, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S442 - S449
  • [6] Comparison of pedometer and accelerometer accuracy under controlled conditions
    Le Masurier, GC
    Tudor-Locke, C
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (05) : 867 - 871
  • [7] Comparisons of four methods of estimating physical activity in adult women
    Leenders, NYJM
    Sherman, WM
    Nagaraja, HN
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (07) : 1320 - 1326
  • [8] Assessment of physical activity with the Computer Science and Applications, Inc., accelerometer: Laboratory versus field validation
    Nichols, JF
    Morgan, CG
    Chabot, LE
    Sallis, JF
    Calfas, KJ
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (01) : 36 - 43
  • [9] Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk
    Schneider, PL
    Crouter, SE
    Lukajic, O
    Bassett, DR
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (10) : 1779 - 1784
  • [10] Step activity monitor: Increased accuracy in quantifying ambulatory activity
    Shepherd, EF
    Toloza, E
    McClung, CD
    Schmalzried, TP
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (05) : 703 - 708