Comparison of pedometer and accelerometer accuracy under controlled conditions

被引:264
作者
Le Masurier, GC [1 ]
Tudor-Locke, C [1 ]
机构
[1] Arizona State Univ E, Dept Exercise & Wellness, Mesa, AZ 85212 USA
关键词
walking; steps/day; transportation; motion sensors;
D O I
10.1249/01.MSS.0000064996.63632.10
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: The purpose of this investigation was to compare the concurrent accuracy of the CSA accelerometer and the Yamax pedometer under two conditions: 1) on a treadmill at five different speeds and 2) riding in a motorized vehicle on paved roads. Methods: In study 1, motion sensor performance was evaluated against actual steps taken during 5-min bouts at five different treadmill walking speeds (54, 67, 80, 94, and 107 m.min(-1)). In study 2, performance was evaluated during a roundtrip (drive I and drive 2) motor vehicle travel on paved roads (total distance traveled was 32.6 km or 20.4 miles). Any steps detected during motor vehicle travel were considered error. Results: In study 1, the Yamax pedometer detected significantly (P < 0.05) fewer steps than actually taken at the slowest treadmill speed (54 m.min(-1)). Further, the pedometer detected fewer steps than the accelerometer at this speed (75.4% vs 98.9%, P < 0.05). There were no differences between instruments compared with actual steps taken at all other walking speeds. In study 2, the CSA detected approximately 17-fold more erroneous steps than the pedometer (approximately 250 vs 15 steps for the total distance traveled, P < 0.05). Conclusions: The magnitude of the error (for either instrument) is not likely an jmportant threat to the assessment of free-living ambulatory populations but may be a problem for pedometers when monitoring frail older adults with slow gaits. On the other hand, CSA accelerometers erroneously detect more nonsteps than the Yamax pedometer under typical motor vehicle traveling conditions. This threat to validity is likely only problematic when using the accelerometer to assess physical activity in sedentary individuals who travel extensively by motor vehicle.
引用
收藏
页码:867 / 871
页数:5
相关论文
共 20 条
  • [1] Validity and reliability issues in objective monitoring of physical activity
    Bassett, DR
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) : S30 - S36
  • [2] Validity of four motion sensors in measuring moderate intensity physical activity
    Bassett, DR
    Ainsworth, BE
    Swartz, AM
    Strath, SJ
    O'Brien, WL
    King, GA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S471 - S480
  • [3] Accuracy of five electronic pedometers for measuring distance walked
    Bassett, DR
    Ainsworth, BE
    Leggett, SR
    Mathien, CA
    Main, JA
    Hunter, DC
    Duncan, GE
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) : 1071 - 1077
  • [4] Objective monitoring of physical activity using motion sensors and heart rate
    Freedson, PS
    Miller, K
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) : S21 - S29
  • [5] Validity of accelerometry for the assessment of moderate intensity physical activity in the field
    Hendelman, D
    Miller, K
    Bagget, C
    Debold, E
    Freedson, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S442 - S449
  • [6] Comparisons of four methods of estimating physical activity in adult women
    Leenders, NYJM
    Sherman, WM
    Nagaraja, HN
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (07) : 1320 - 1326
  • [7] MAHAR MT, 2000, RES Q EXERC SPORT S2, V71, pS1
  • [8] RAVEN PB, 2000, MED SCI SPORT EXER S, V33, pS439
  • [9] Step activity monitor: Increased accuracy in quantifying ambulatory activity
    Shepherd, EF
    Toloza, E
    McClung, CD
    Schmalzried, TP
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (05) : 703 - 708
  • [10] SILVERMAN GJ, 1993, IMMUNOMETHODS, V2, P17