Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses

被引:29
作者
Biau, D. [1 ]
Mullins, M. M. [1 ]
Judet, T. [1 ]
Piriou, P. [1 ]
机构
[1] Hop Raymond Poincare, Serv Chirurg Orthoped & Traumatol, F-92380 Garches, France
关键词
total knee replacement; cohort study; statistical analysis; rotating platform; fixed platform;
D O I
10.1007/s00167-006-0070-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Since the late 1970s, mobile-bearing total knee designs have been advocated as having theoretical advantages over fixed-bearing total knee replacements. At present there is no consensus as to whether there are any differences in clinical results between the two designs. We present the results of two consecutive cohorts each of over 100 prosthesis. The first cohort underwent a fixed-bearing prosthesis, whilst the second cohort received the mobile bearing variant of the same prosthesis. Both groups were assessed pre- and post-operatively using the American Knee Society knee and function scores as well as range of movement and the presence or absence of anterior knee pain. No difference was found statistically significant between the groups, either for the knee score (P=0.068), the function score (P=0.26), the range of movement (P=0.11) or the proportions of anterior knee pain (P=0.06). It is our opinion that mobile bearing knee prosthesis have still to prove their theoretical advantages in clinical practice
引用
收藏
页码:927 / 933
页数:7
相关论文
共 33 条
[1]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[2]  
BARRACK RL, 2001, CLIN ORTHOP RELAT R, V392, P46
[3]  
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[4]  
BERT JM, 1990, CLIN ORTHOP RELAT R, V254, P211
[5]  
Briard J L, 1989, J Arthroplasty, V4 Suppl, pS87, DOI 10.1016/S0883-5403(89)80013-0
[6]   THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[7]   The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses - a biomechanical study [J].
Cheng, CK ;
Huang, CH ;
Liau, JJ ;
Huang, CH .
CLINICAL BIOMECHANICS, 2003, 18 (03) :231-236
[8]  
Chiu K Y, 2001, J Orthop Surg (Hong Kong), V9, P45
[9]   Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[10]  
DLIMA DD, 2000, CLIN ORTHOP RELAT R, V380, P151