Dual lifetime referenced trace ammonia sensors

被引:36
作者
Waich, K. [1 ]
Borisov, S. [1 ]
Mayr, T. [1 ]
Klimant, I. [1 ]
机构
[1] Graz Univ Technol, Inst Analyt Chem, Chemo & Biosensor Grp, A-8010 Graz, Austria
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 139卷 / 01期
基金
奥地利科学基金会;
关键词
Trace ammonia; Optical sensor; Dual lifetime referencing (DLR); CARBON-DIOXIDE; MEMBRANE;
D O I
10.1016/j.snb.2008.10.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual lifetime referencing is applied to trace ammonia sensors. Two schemes are presented to achieve luminescence lifetime based measurements in the frequency domain: the first is based on a resonance energy transfer (RET) system with eosin ethylester as indicator applying a coumarin derivative as donor. The second consists of a resonance energy transfer cascade with a coumarin derivative, sulforhodamine B and the absorption dye bromophenol blue as ammonia-sensitive dye. The large Stokes shift due to the energy transfer and the resulting spectral properties of the sensing layers enable dual lifetime referencing using an Ir(III)-coumarin complex for both ammonia detection systems. The sensing systems are applicable for the monitoring of ammonia in the range of either 1-5000 mu g/l or 50-50,000 mu g/l, respectively. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 17 条
[1]   FIBER OPTIC AMMONIA GAS SENSING PROBE [J].
ARNOLD, MA ;
OSTLER, TJ .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1137-1140
[2]   Synthesis of an ammonium ionophore and its application in a planar ion-selective electrode [J].
Benco, JS ;
Nienaber, HA ;
McGimpsey, WG .
ANALYTICAL CHEMISTRY, 2003, 75 (01) :152-156
[3]   Ultrabright oxygen optodes based on cyclometalated lridium(III) coumarin complexes [J].
Borisov, Sergey M. ;
Klimant, Ingo .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7501-7509
[4]   Chemical sensing using an integrated microfluidic system based on the Berthelot reaction [J].
Daridon, A ;
Sequeira, M ;
Pennarun-Thomas, G ;
Dirac, H ;
Krog, JP ;
Gravesen, P ;
Lichtenberg, J ;
Diamond, D ;
Verpoorte, E ;
de Rooij, NF .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) :235-243
[5]   Dual lifetime referencing as applied to a chloride optical sensor [J].
Huber, C ;
Klimant, I ;
Krause, C ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :2097-2103
[6]  
Klimant I, 2001, SPR S FLUOR, V1, P257
[7]   Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing [J].
Liebsch, G ;
Klimant, I ;
Krause, C ;
Wolfbeis, OS .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4354-4363
[8]   EVALUATION OF TRANSIENT RESPONSES OF AMMONIA-SELECTIVE POTENTIOMETRIC ELECTRODES FOR QUANTITATIVE APPLICATIONS [J].
LOVE, MD ;
PARDUE, HL ;
PAGAN, G .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1269-1276
[9]   Dual lifetime referenced optical sensor membrane for the determination of copper(II) ions [J].
Mayr, T ;
Klimant, I ;
Wolfbeis, OS ;
Werner, T .
ANALYTICA CHIMICA ACTA, 2002, 462 (01) :1-10
[10]  
MEYERHOFF ME, 1982, CLIN CHEM, V28, P1973