A chloride ion-selective solvent polymeric membrane electrode based on a hydrogen bond forming ionophore

被引:152
作者
Xiao, KP [1 ]
Buhlmann, P [1 ]
Nishizawa, S [1 ]
Amemiya, S [1 ]
Umezawa, Y [1 ]
机构
[1] UNIV TOKYO,SCH SCI,DEPT CHEM,TOKYO 113,JAPAN
关键词
FIELD-EFFECT TRANSISTORS; NEUTRAL CARRIERS; GAS-PHASE; ANION SELECTIVITIES; AMMONIUM-COMPOUNDS; ORGANIC-COMPOUNDS; HALIDE ANIONS; RECOGNITION; SITES; RECEPTORS;
D O I
10.1021/ac961035d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chloride-selective solvent polymeric membrane electrode based on a neutral hydrogen bond forming ionophore, poly(vinyl chloride) (PVC), the plasticizer 2-nitrophenyl octyl ether (o-NPOE), and cationic sites (50 mol %, relative to the ionophore) is described. At pH 7.0 (HEPES buffer), this electrode responds to chloride in a linear range from 10(-5) to 10(-2) M with a slope of (-54.0 +/- 1.0) mV/decade and a detection limit of (6.5 +/- 3.0) x 10(-6) M. As compared to conventional anion-exchanger electrodes, the interference of SCN-, Br-, NO3-, I-, and even salicylate is considerably reduced, as shown by the selectivity coefficients determined with the matched potential method (MPM) in the chloride concentration range 10(-2.34)-10(-2.04) M (log KPCl,jpot (MPM): Sal(-), +1.8; SCN-, +1.6; NO3-, +0.7; I-, +0.5; Br-, +0.4). Because the discrimination of the more hydrophilic anions SO42-, HSO3-/SO32-, OAc-, HCO3-, and H2PO4-/HPO42- is too large for a determination of accurate selectivity coefficients in this high chloride concentration range, corresponding values for the range 10(-5.00)-10(-4.70) M Cl- have been determined (log K-Cl,j(pot) (MPM): SO42-, -1.2; HSO3-/SO32-, -2.0; OAC-, -2.3; HCO3-, -2.6; H2PO4-/HPO42-, < -3.5), showing here, too, a good selectivity for Cl-. The chloride ion concentration in certified control horse serum was determined by the standard addition method as 102.1 mM with a coefficient of variation of 0.42% (n = 6). This result is in excellent agreement with the certified value of 102.3 mM, as determined by coulometry, and demonstrates the applicability of this sensor for measurements in biological samples. The selectivity upon storage of the electrode in buffer solution for 4 weeks decreases but is stilt considerably better than that for a freshly prepared anion-exchanger electrode.
引用
收藏
页码:1038 / 1044
页数:7
相关论文
共 59 条
  • [31] HUBL W, 1994, CLIN CHEM, V40, P1528
  • [32] A NEW DOUBLE-BARRELED, IONOPHORE-BASED MICROELECTRODE FOR CHLORIDE-IONS
    KONDO, Y
    BUHRER, T
    SEILER, K
    FROMTER, E
    SIMON, W
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1989, 414 (06): : 663 - 668
  • [33] HYDROGEN-BONDING IN GAS-PHASE ANIONS - AN EXPERIMENTAL INVESTIGATION OF THE INTERACTION BETWEEN CHLORIDE-ION AND BRONSTED ACIDS FROM ION-CYCLOTRON RESONANCE CHLORIDE EXCHANGE EQUILIBRIA
    LARSON, JW
    MCMAHON, TB
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (03) : 517 - 521
  • [34] PARTITION COEFFICIENTS AND THEIR USES
    LEO, A
    HANSCH, C
    ELKINS, D
    [J]. CHEMICAL REVIEWS, 1971, 71 (06) : 525 - +
  • [35] Morf W.E., 1981, The principles of ion-selective electrodes and of membrane transport. M. W.E, V2
  • [36] ANION RECOGNITION BY UREA AND THIOUREA GROUPS - REMARKABLY SIMPLE NEUTRAL RECEPTORS FOR DIHYDROGENPHOSPHATE
    NISHIZAWA, S
    BUHLMANN, P
    IWAO, M
    UMEZAWA, Y
    [J]. TETRAHEDRON LETTERS, 1995, 36 (36) : 6483 - 6486
  • [37] Nishizawa S., UNPUB
  • [38] OCONNOR KM, 1993, ANAL PROC, V30, P137
  • [39] LIFE TIME OF NEUTRAL CARRIER BASED ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES
    OESCH, U
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (04) : 692 - 700
  • [40] DESIGN OF ANION-SELECTIVE MEMBRANES FOR CLINICALLY RELEVANT SENSORS
    OESCH, U
    AMMANN, D
    PHAM, HV
    WUTHIER, U
    ZUND, R
    SIMON, W
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1179 - 1186