Can We Really Close the Loop and How Soon? Accelerating the Availability of an Artificial Pancreas: A Roadmap to Better Diabetes Outcomes

被引:97
作者
Kowalski, Aaron J. [1 ]
机构
[1] Juvenile Diabet Res Fdn Int, New York, NY 10005 USA
关键词
INSULIN DELIVERY; TYPE-1; HYPOGLYCEMIA;
D O I
10.1089/dia.2008.0031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Development of a closed-loop artificial pancreas has been a long-time goal that could transform diabetes management. The primary limitation until recent years was the lack of a robust and portable continuous glucose sensor. There has been significant progress over the past 5 years in the development and commercialization of continuous glucose monitoring (CGM) devices. Used adjunctively, CGM has been demonstrated to add significant value in improving diabetes management by increasing time spent in glycemic targets and improving overall glycemic control. However, these benefits are limited by the human user's finite capacity to respond to the data provided by the device. By automating even a portion of the insulin delivery functionality of combined sensor/pump systems via computer algorithm, impending excursions could be handled more quickly and effectively. This review will describe very promising preliminary closed-loop studies, describe a potential roadmap to an artificial pancreas that will be safe and effective, and propose a solution-a hypo-and hyperglycemia minimizing control-to-range approach-that may allow for near-term delivery of a semiautomated system to people with diabetes.
引用
收藏
页码:S113 / S119
页数:7
相关论文
共 28 条
[1]  
AMIEL S, 2009, CLOSING GAP CLOSED L
[2]  
Bequette B Wayne, 2005, Diabetes Technol Ther, V7, P28, DOI 10.1089/dia.2005.7.28
[3]   Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes [J].
Bode, BW ;
Schwartz, S ;
Stubbs, HA ;
Block, JE .
DIABETES CARE, 2005, 28 (10) :2361-2366
[4]   Duration of Nocturnal Hypoglycemia Before Seizures [J].
Buckingham, Bruce ;
Wilson, Darrell M. ;
Lecher, Todd ;
Hanas, Ragnar ;
Kaiserman, Kevin ;
Cameron, Fergus .
DIABETES CARE, 2008, 31 (11) :2110-2112
[5]  
Buckingham Bruce, 2005, Diabetes Technol Ther, V7, P440, DOI 10.1089/dia.2005.7.440
[6]   Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension [J].
Buckingham, Bruce ;
Cobry, Erin ;
Clinton, Paula ;
Gage, Victoria ;
Caswell, Kimberly ;
Kunselman, Elizabeth ;
Cameron, Fraser ;
Chase, H. Peter .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (02) :93-97
[7]   The Barrier of Hypoglycemia in Diabetes [J].
Cryer, Philip E. .
DIABETES, 2008, 57 (12) :3169-3176
[8]   Detection of a Meal Using Continuous Glucose Monitoring implications for an artificial β-cell [J].
Dassau, Eyal ;
Bequette, B. Wayne ;
Buckingham, Bruce A. ;
Doyle, Francis J., III .
DIABETES CARE, 2008, 31 (02) :295-300
[9]   Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring [J].
Deis, Dorothee ;
Bolinder, Jan ;
Riveline, Jean-Pierre ;
Battelino, Tadej ;
Bosi, Emanuele ;
Tubiana-Rufi, Nadia ;
Kerr, David ;
Phillip, Moshe .
DIABETES CARE, 2006, 29 (12) :2730-2732
[10]   Continuous glucose monitoring in children with type 1 diabetes [J].
不详 .
JOURNAL OF PEDIATRICS, 2007, 151 (04) :388-393