SQUID detected NMR in microtesla magnetic fields

被引:80
作者
Matlachov, AN [1 ]
Volegov, PL [1 ]
Espy, MA [1 ]
George, JS [1 ]
Kraus, RH [1 ]
机构
[1] Los Alamos Natl Lab, Biophys Grp, Los Alamos, NM 87545 USA
关键词
D O I
10.1016/j.jmr.2004.05.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have built an NMR system that employs a superconducting quantum interference device (SQUID) detector and operates in measurement fields of 2-25 muT. The system uses a pre-polarizing field from 4 to 30 mT generated by simple room-temperature wire-wound coils that are turned off during measurements. The instrument has an open geometry with samples located outside the cryostat at room-temperature. This removes constraints on sample size and allows us to obtain signals from living tissue. We have obtained I H NMR spectra from a variety of samples including water, mineral oil, and a live frog. We also acquired gradient encoded free induction decay (FID) data from a water-plastic phantom in the muT regime, from which simple projection images were reconstructed. NMR signals from samples inside metallic containers have also been acquired. This is possible because the penetration skin depth is much greater at the low operating frequencies of this system than for conventional systems. Advantages to ultra-low field NMR measurements include lower susceptibility artifacts caused by high strength polarizing and measurement fields, and negligible line width broadening due to measurement field inhomogeneity, reducing the burden of producing highly homogeneous fields. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 31 条
[21]   NMR - A powerful tool for industrial process control and quality assurance [J].
Pykett, IL .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) :721-723
[22]   On- and off-resonance spin-lock MR imaging of normal human brain at 0.1T:: Possibilities to modify image contrast [J].
Ramadan, UA ;
Markkola, AT ;
Halavaara, J ;
Tanttu, J ;
Häkkinen, AM ;
Aronen, HJ .
MAGNETIC RESONANCE IMAGING, 1998, 16 (10) :1191-1199
[23]   Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device [J].
Schlenga, K ;
McDermott, R ;
Clarke, J ;
de Souza, RE ;
Wong-Foy, A ;
Pines, A .
APPLIED PHYSICS LETTERS, 1999, 75 (23) :3695-3697
[24]   DC SQUID-BASED NMR DETECTION FROM ROOM-TEMPERATURE SAMPLES [J].
SETON, HC ;
BUSSELL, DM ;
HUTCHISON, JMS ;
NICHOLSON, I ;
LURIE, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (11) :2133-2138
[25]   A 4.2 K receiver coil and SQUID amplifier used to improve the SNR of low-field magnetic resonance images of the human arm [J].
Seton, HC ;
Hutchison, JMS ;
Bussell, DM .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (02) :198-207
[26]   A tuned SQUID amplifier for MRI based on a DOIT flux locked loop. [J].
Seton, HC ;
Hutchison, JMS ;
Bussell, DM .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) :3213-3216
[27]   Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays [J].
Sodickson, DK ;
Manning, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) :591-603
[28]   NMR IMAGING IN THE EARTHS MAGNETIC-FIELD [J].
STEPISNIK, J ;
ERZEN, V ;
KOS, M .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :386-391
[29]   A MAGNETIC SHIELDED ROOM DESIGNED FOR MAGNETOENCEPHALOGRAPHY [J].
SULLIVAN, GW ;
LEWIS, PS ;
GEORGE, JS ;
FLYNN, ER .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04) :765-770
[30]  
VOLEGOV P, IN PRESS MAGN RESON