diffusion;
heavy element;
non-destructive imaging;
waste disposal;
X-ray CT;
D O I:
10.1016/S0013-7952(99)00130-1
中图分类号:
P5 [地质学];
学科分类号:
0709 ;
081803 ;
摘要:
X-ray computerized tomography (CT) was applied for the first time to the measurement of diffusion coefficients of heavy ions in water-saturated clay and rock. The mass absorption coefficient of X-rays is high for heavy elements. Thus the migration of heavy ions in the porous samples was measured by the spatio-temporal change in intensity of X-ray CT images. The measurements of diffusion coefficients of I- in bulk water, synthesized saponite (96.6 wt% H2O) and rhyolitic lava (porosity 24%) were demonstrated successfully. The one-dimensional transient migration of I- was imaged by a medical X-ray CT scanner with an in-plane resolution of 0.31 mm. The measured I- diffusivity in bulk water agreed well with that of the literature. Because non-destructive, quick and three-dimensional data acquisition is possible, X-ray CT has advantages over conventional methods for laboratory experiments on heavy-element diffusion in porous media. (C) 2000 Elsevier Science B.V. All rights reserved.
机构:
Department of Civil Engineering, Colorado State University, Fort Collins, CO 80523, United StatesDepartment of Civil Engineering, Colorado State University, Fort Collins, CO 80523, United States
机构:
Department of Civil Engineering, Colorado State University, Fort Collins, CO 80523, United StatesDepartment of Civil Engineering, Colorado State University, Fort Collins, CO 80523, United States