Improved design of cementless hip stems using two-dimensional functionally graded materials

被引:45
作者
Hedia, H. S. [1 ]
Shabara, M. A. N. [1 ]
El-Midany, T. T. [1 ]
Fouda, N. [1 ]
机构
[1] Univ Mansoura, Fac Engn, Dept Prod Engn & MC Design, Mansoura 35516, Egypt
关键词
functionally graded materials; cementless hip stem; von Mises stress; interface shear stress;
D O I
10.1002/jbm.b.30509
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Increasingly, it is acknowledged that bone resorption around cementless hip implants may cause future problems. The solution is frequently sought in reducing implant stiffness. However, this confronts the designer with a true design conflict: how to reduce the stiffness without excessively loading the proximal bone/prosthesis interface? The aim of this work is to improve the design of cementless hip stem material, using two-dimensional (2D) functionally graded material (FGM) concept in order to solve the above problems. Two models were used in this analysis, using three materials with different elastic moduli, E-1, E-2, and E-3. In model I, the elastic moduli E-1, and E-2 gradually change along the upper stem surface, while E-3 is maintained constant along all the lower surface of the stem. However, in model II, the elastic moduli E-1 and E-2 gradually change along the lower stem surface, while E-3 is maintained constant all along the upper stem surface. It is found that the recommended model is model I, which has three distinct materials of hydroxyapatite, Bioglass, and collagen. The recommended design of 2D FGM is expected to reduce the stress shielding by 91% and 12%, respectively, compared with titanium stem and model II of FGM. It is found that this new design reduces the maximum interface shear stress at the lateral and medial sides of the femur by about 50%, compared with titanium stem. Furthermore, the maximum interface shear stress is reduced by about 17% and 11% at the lateral and medial sides of the femur, respectively, compared with that of model II of FGM. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 19 条
[1]
Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study on the goat [J].
Buma, P ;
vanLoon, PJM ;
Versleyen, H ;
Weinans, H ;
Slooff, TJJH ;
deGroot, K ;
Huiskes, R .
BIOMATERIALS, 1997, 18 (18) :1251-1260
[2]
Hedia H., 2004, INT J MECH MATER DES, V1, P329, DOI [10.1007/s10999-005-3307-4, DOI 10.1007/S10999-005-3307-4]
[3]
Hedia HS, 1996, BIO-MED MATER ENG, V6, P199
[4]
Hedia HS, 1996, BIO-MED MATER ENG, V6, P135
[5]
Comparison of one-dimensional and two-dimensional functionally graded materials for the backing shell of the cemented acetabular cup [J].
Hedia, HS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 74B (02) :732-739
[6]
Hedia HS, 2004, BIO-MED MATER ENG, V14, P133
[7]
Hedia HS, 1997, BIO-MED MATER ENG, V7, P83
[8]
HUISKES R, 1992, CLIN ORTHOP RELAT R, P124
[9]
3-DIMENSIONAL SHAPE RECONSTRUCTION AND FINITE-ELEMENT ANALYSIS OF FEMUR BEFORE AND AFTER THE CEMENTLESS TYPE OF TOTAL HIP-REPLACEMENT [J].
KANG, YK ;
PARK, HC ;
YOUM, Y ;
LEE, IK ;
AHN, MH ;
IHN, JC .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (06) :497-504
[10]
Self-organization mechanism in a bone-like hydroxyapatite/collagen nanocomposite synthesized in vitro and its biological reaction in vivo [J].
Kikuchi, M ;
Itoh, S ;
Ichinose, S ;
Shinomiya, K ;
Tanaka, J .
BIOMATERIALS, 2001, 22 (13) :1705-1711