Interaction of spiral ganglion neuron processes with alloplastic materials in vitro

被引:38
作者
Brors, D
Aletsee, C
Schwager, K
Mlynski, R
Hansen, S
Schäfers, M
Ryan, AF
Dazert, S
机构
[1] Univ Calif San Diego, Sch Med, Dept Surg, Div Otolaryngol, La Jolla, CA 92093 USA
[2] VA Med Ctr, La Jolla, CA 92093 USA
[3] Univ Wurzburg, Dept Otorhinolaryngol Head & Neck Surg, D-97080 Wurzburg, Germany
[4] Univ Wurzburg, Dept Neurol, D-97080 Wurzburg, Germany
关键词
alloplastic material; spiral ganglion; neurite growth; cochlear implant;
D O I
10.1016/S0378-5955(02)00355-6
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 [病理学与病理生理学]; 100213 [耳鼻咽喉科学];
摘要
The cochlear implant (CI) involves the introduction of alloplastic materials into the cochlea. While current implants interact with cochlear neurons at a distance, direct interactions between spiral ganglion (SG) neurites and implants could be fostered by appropriate treatment with neurotrophic factors. The interactions of fibroblasts and osteoblasts with alloplastic materials have been well studied in vitro and in vivo. However, interactions of inner ear neurons with such alloplastic materials have yet to be described. To investigate survival and growth behavior of SG neurons on different materials, SG explants from post-natal day 5 rat SG were cultured for 72 h in the presence of neurotrophin-3 (10 ng/ml) on titanium, gold, stainless steel, platinum, silicone and plastic surfaces that had been coated with laminin and poly-L-lysine. Neurite outgrowth was investigated after immunohistological staining for neurofilament, by image analysis to determine neurite extension and directional changes. Neurite morphology and adhesion to the alloplastic material were also evaluated by scanning electron microscopy (SEM). On titanium, SG neurites reached the highest extent of outgrowth, with an average length of 662 pm and a mean of 31 neurites per explant, compared to 568 Pin and 21 neurites on gold, 574 mum and 24 neurites on stainless steel, 509 mum and 16 neurites on platinum, 281 mum and 12 neurites on silicone and 483 pm and 31 neurites on plastic. SEM revealed details of adhesion of neurites and interaction with non-neuronal cells. The results of this study indicate that the growth of SG neurons in vitro is strongly influenced by alloplastic materials, with titanium exhibiting the highest degree of biocompatibility with respect to neurite extension. The knowledge of neurite interaction with different alloplastic materials is of clinical interest, as development in CI technology leads to closer contact of implanted electrodes with surviving inner ear neurons. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:110 / 121
页数:12
相关论文
共 66 条
[1]
ALETSEE C, 2002, HEARING RES, V37, P1
[2]
Berruecos P, 2000, AUDIOLOGY, V39, P221
[3]
Removal of a cochlea implant with chronic granulation labyrinthitis and foreign body reaction. [J].
Bertuleit, H ;
Groden, C ;
Schäfer, HJ ;
Leuwer, R .
LARYNGO-RHINO-OTOLOGIE, 1999, 78 (06) :304-306
[4]
BISLAND J, 1999, J NEUROSCI METH, V92, P75
[5]
BJURSTEN LM, 1991, BONE-BIOMATERIAL INTERFACE, P165
[6]
FACTORS PREDICTING POSTOPERATIVE SENTENCE SCORES IN POSTLINGUISTICALLY DEAF ADULT COCHLEAR IMPLANT PATIENTS [J].
BLAMEY, PJ ;
PYMAN, BC ;
CLARK, GM ;
DOWELL, RC ;
GORDON, M ;
BROWN, AM ;
HOLLOW, RD .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1992, 101 (04) :342-348
[7]
Histories of cochlear implantation [J].
Blume, SS .
SOCIAL SCIENCE & MEDICINE, 1999, 49 (09) :1257-1268
[8]
Role of material surfaces in regulating bone and cartilage cell response [J].
Boyan, BD ;
Hummert, TW ;
Dean, DD ;
Schwartz, Z .
BIOMATERIALS, 1996, 17 (02) :137-146
[9]
GEOMETRY OF ISOLATED SENSORY NEURONS IN CULTURE - EFFECTS OF EMBRYONIC AGE AND CULTURE SUBSTRATUM [J].
BRAY, D ;
BUNGE, MB ;
CHAPMAN, K .
EXPERIMENTAL CELL RESEARCH, 1987, 168 (01) :127-137
[10]
Brunette D., 1996, NANOFABRICATION BIOS, P335